Scholars Central

Research articlePublished 22 Dec 2021

Anti-microbial Effect of Filtered 222 nm Excimer Lamps in a Hospital Waiting Area

Authors: Jacob Thyrsted, Stine Yde Nielsen, Christian Kanstrup Holm, Søren Helbo Skaarup, Andreas Fløe Hvass, Elisabeth Bendstrup, Pernille Hauschildt, Sara Moeslund Joensen

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Background: Hospital aquired infections are a considerable challenge for vulnerable patients. Traditional anti-microbial mercury lamps emit light at 254 nm and have well established anti-microbial effects. Their use in populated areas is, however, hindered by their carcinogenic properties. This is in contrast to anti-microbial lamps based on Krypton Chloride (KrCl), demonstrated to have no carcinogenic potential. These lamps emit light with a peak intensity at 222 nm and have broad bactericidal and viricidal effects including inactivation of SARS-CoV2. It is, however, unclear how 222 nm lamps perform in a real-life setting. In this study we aimed to assess the anti-microbial efficacy of filtered 222 nm excimer lamps in a real-world setting at an out-patient pulmonology clinic. Methods: Filtered KrCl 222nm excimer lamps (UV222 TM lamps) were installed in an out-patient waiting area at the pulmonology section ta AarhuUs niversity Hospital. Furniture sufaces were sampled for bacterial load in a single-arm interventional longitudinasl tudy with and without exposure to filtered 222 nm UVC-light. Furthermore, bacterial species were identified using MALDIToF mass-spectrometry. Findings: Filtered 222 nm UVC- light significantly reduced the number of colony-forming-units. Pathogenic bacteria such as Staphylococcus aureus and Staphylococcus epidermidis were detected only in the non-exposed areas suggesting that these species in particular are highly sensitive to inactivation by 222 nm UVC-light. Conclusion: Filtered UVC-Light is efficient in reducing bacteria from exposed surfaces in the real-life setting of patient waiting area and hereby supports the use of the 222 nm UVC technologies to reduce bacterial load and thus the spread of infectious disease in a hospital setting.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Biomedical Sciences.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Biomedical Sciences
  • SubjectImmunology & Microbiology
  • SubjectInfectious Diseases
  • SubjectPulmonology & Respiratory
  • BylineArticles whose byline prints “Jacob Thyrsted”
  • BylineArticles whose byline prints “Stine Yde Nielsen”
  • BylineArticles whose byline prints “Christian Kanstrup Holm”
  • BylineArticles whose byline prints “Søren Helbo Skaarup”
  • BylineArticles whose byline prints “Andreas Fløe Hvass”
  • BylineArticles whose byline prints “Elisabeth Bendstrup”
  • BylineArticles whose byline prints “Pernille Hauschildt”
  • BylineArticles whose byline prints “Sara Moeslund Joensen”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels