Conference abstract · 2020
Conference abstractPublished 13 Jul 2015
Predicting primary angle closure suspects using anterior segment OCT: A new approach
University of Montreal, Canada
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Objective: To propose a novel non-invasive method for screening patients at risk of angle closure and thus the need for laser peripheral iridotomy using anterior segment OCT imaging. Methods: Horizontal scans of the nasal and temporal anterior chamber angles in glaucoma suspect patients were performed at 870 nm wavelength Fourier-domain OCT (Spectralis-Heidelberg). Schwalbe’s line (S) was identified on the images and using the integrated caliper tool, a line was drawn to the nearest point of the iris (S-I). A glaucoma specialist carried out gonioscopy and irido-corneal angles were graded according to a Shaffer grade. Anterior chamber depths as well as irido-corneal angle measurements were also carried out using Pentacam imaging. Spearman analysis was performed to assess the correlation between S-I and Shaffer grades as well as between the different Pentacam measurements and Shaffer grades. Furthermore Tukey-Kramer HSD analysis was also carried out to evaluate the statistical differences between the means of S-I and each of the Pentacam measurements for each Shaffer grade. Results: Thirty-four images from forty enrolled subjects were available for analysis. Schwalbe’s line was identifiable in 94% of the total images. Correlation coefficients between S-I measurements and Shaffer grades were 0.81 and 0.77 for nasal and temporal quadrants respectively. The correlation was much lower with Pentacam-measured anterior chamber depth and irido-corneal angle (r=0.55 and 0.37 respectively). The means of S-I for gonioscopically occludable angles were statistically different than the means for gonioscopically wide-open angles. On the other hand the same statistical difference could not be achieved when comparing the means for Pentacam-measured anterior chamber depth and irido-corneal angle with gonioscopic Shaffer grade. The diagnostic cutoff value of S-I for occludable angles was established at 300 µm. Conclusion: The measurement of S-I using anterior segment OCT imaging strongly correlates with gonioscopy and may be a suitable non-invasive alternative for evaluating the risk for angle closure.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2013
Lens Thickness and Position of Primary Angle Closure Measured by Anterior Segment Optical Coherence Tomography
Research article · 26 Sep 2024
A Comparison of Retinal Microvascular Density using OCTA in Primary Angle Closure Suspects, Primary Angle Closure Glaucoma, Pseudo Exfoliation Glaucoma and Healthy Controls
Research article · 2022
A Comparison of Retinal Microvascular Density using OCTA in Primary Angle Closure Suspects, Primary Angle Closure Glaucoma, Pseudo Exfoliation Glaucoma and Healthy Controls
Conference abstract · 27 Oct 2021
Role of routine laser peripheral iridotomy without pliocarpine in primary angle closure suspects during covid pandemic
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “Dan Samaha”
