Conference abstractPublished 26 Apr 2024
Variance in the macular sublayersâ?? volume as a diagnostic tool for primary open angle glaucoma
Shiraz University of Medical science, Iran; Wills Eye Glaucoma Service, USA
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Statement of the Problem: Glaucoma is an optic neuropathy and typically progressive if left untreated. The advent of Optical Coherence Tomography (OCT) revolutionized the diagnosis of glaucoma. In Previous studies ganglion cell complex and inner retinal layer thicknesses have excellent diagnostic accuracy for glaucoma detection. We hypothesized that glaucoma might alter the normal thickness proportion between retinal sublayers as well, and this feature might have a potential for detecting glaucoma. We assessed the variance of macular sublayers’ volume in patients with glaucoma and healthy controls. We also evaluated the accuracy of this method as a possible diagnostic tool for detecting glaucoma. Methodology: In this case–control observational study 63 cases of primary open-angle glaucoma and 57 healthy controls were included. Spectralis OCT2 was used to capture macular volumetric scans at the 6 mm ETDRS circle for each retinal sublayer. The retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, inner nuclear layer, outer plexiform layer, outer nuclear layer, and outer retinal layers (external limiting membrane to the retinal pigment epithelium) were the macular sublayers included in this study. Standard deviation (SD) and coefficient of variation (CoV) of macular sublayers’ volume were calculated. In order to compare each variable between groups, an unpaired Student t test (or its nonparametric equivalent) was used. The receiver operating characteristic curve (ROC) was used to investigate the discriminative ability of each parameter. Findings: The SD (of all sublayers’ volume) was greater in the glaucomatous eyes compared with controls. The same pattern was observed for CoV. The best cutoff value for the CoV was 6.712. The CoV and ganglion cell layer (GCL) volume revealed similar sensitivity (80.75) at 95% specificity for diagnosing glaucoma. The CoV detected five patients with glaucoma who had normal GCC volume. Conclusion: Retinal sublayer variance parameters (SD, and particularly CoV) could be a viable addition to the prevailing macular OCT indices for improving glaucoma diagnosis.
Subjects
Ophthalmology & OptometryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Clinical and Experimental Ophthalmology
- SubjectOphthalmology & Optometry
- BylineArticles whose byline prints “Kiana Khatami”
- BylineArticles whose byline prints “M Hossein Nowroozzadeh”
- BylineArticles whose byline prints “Alireza Estedlal”
- BylineArticles whose byline prints “Zahra Emadi”
- BylineArticles whose byline prints “Athar Zarei”
- BylineArticles whose byline prints “Reza Razeghinejad”

