Scholars Central

Case reportPublished 2021

Amperometric determination of yttrium with β-hydroxyethylimide solution

Authors: N.K.H. Kutlimurotova, Z.A. Smanova, Yuldasheva M.R.

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Yttrium and its compounds are used to create high-temperature ceramics, quantum mechanical amplifiers, lasers, phosphors, emission materials, dielectrics, high-power halogen lighting lamps, catalysts, etc. Its valuable properties are high temperature stability, enhanced strength, corrosion and radiation resistance. The basis of the work is the development of new and improvement of existing analytical methods for determining the content with high sensitivity, accuracy and a wide range of detectable concentrations. Optimized conditions for amperometric titration (AT) of the method for determining the mass concentrations of yttrium with β-hydroxyethylimide reagent in various natural objects with improved metrological indicators (correctness, reproducibility, expansion the determination range for contaminant content, selectivity, etc.). Based on the detected volt-ampere characteristics of β-hydroxyethylimide on platinum disks of microanode in the presence of various background electrolytes in a dimethylformamide solutions, it follows that amperometric indication of the end point of titration (EPT) of yttrium ions with two indicator electrodes should be performed at a voltage of 0.20- 1.20 V. When titrated with β-hydroxyethylimide solutions, depending on the nature of the background used, arisen anodic current of the AT titrant should conduct in the potential range of 0.65 -0.8 V. The effect of different in nature background electrolytes and buffer mixtures with pH 1- 12 on the results of titration was investigated. It was found that yttrium is sufficiently titrated in weakly acidic medium (pH 4.28-6.36), and in neutral and basic medium – they form less-stable complex compounds with this reagent and, in turn, are not titrated well enough. For a statistical evaluation of the accuracy of the determined method of determining the amount of yttrium with β-hydroxyethylimide solution, many different multiple (at least 4 times) repetitions of each determination were carried out under the following optimal conditions: 2.0 ml of 0.04 M universal buffer solution (pH 1.81)), the difference potentials ΔE = 0.8 V, the total volume of the test solution is 10 ml. Experiments have shown that AT ions of yttrium complexes are obtained in the composition of Me:Reagent = 1:1. The proportional relationship between the amount of metal taken and the amount of reagent consumed is fairly well observed.

Subjects

Chemistry

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Insights in Analytical Electrochemistry.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalInsights in Analytical Electrochemistry
  • SubjectChemistry
  • BylineArticles whose byline prints “N.K.H. Kutlimurotova”
  • BylineArticles whose byline prints “Z.A. Smanova”
  • BylineArticles whose byline prints “Yuldasheva M.R.”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels