Scholars Central

Conference abstractPublished 29 Aug 2020

Case Study: Energy-Management System for a Grid-Connected Residential DC Microgrid

Authors: Víctor Manuel Sámano Ortega

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Power consumption increase and the never-ending in­dustrial demand on electrical energy haveresulted in a depletionof conventional generation resources, such as fossil fuels.On the other hand, renewable energiesare still facing issues for massive generation and supply due to its unpredictable nature.One alternative to solve these issues isthe distributed generation techniques sourced by renewable energy which require efficient and highlyreli­able power management schemes in microgrids. Among the investigations carried out on energymanage­ment systems (EMSs) in microgrids(μGs) there are differ­ent approaches that includes scheduling strategies, cost reduction or energy commercialization, among others. However, in author’s opinion, some of themare oversim­plified and other considers ideal conditions, which are not satisfied in real-life situations.Therefore, the design and implementation of anEMS applied to aresidential di­rect current microgrid (DC-μG) is presented in this work. The proposed residentialDC-μG is designed to provide a maximum power of 1 kW by using two photovoltaic arrays(PAs) of 500 W, a battery bank (BB) of 120 V–115 Ah, a supercapacitor module of 0.230 F and abidirection­al DC–AC converter linked to the AC main grid (MG). The EMS works as a centralized manager and it defines the working operation mode for each section of the DC-μG. The operationmodes are based on: (1) the DC-link bus voltage, (2) the generated or demanded power to eachsection of the DC-μG and (3) the BB’s state of charge. The proposed EMS—during the several workingoperation modes and at the same time— can obtain the maximum energy from the PAs, reducethe energy consumption from the main grid and keep the DC-link bus voltage inside a range of190 V ± 5%. The EMS and local controllers are implemented by using Lab­VIEW and NI myRIO-1900platforms. Moreover, experi­mental results during connection and disconnection of each DC-μGsections and different on-the-fly transitions are reported, these results focus on the behavior of the DCbus, which shows the DC bus robustness and stability underdifferent scenarios.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Chemical Biology & Pharmaceutical Chemistry.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Chemical Biology & Pharmaceutical Chemistry
  • SubjectChemistry
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “Víctor Manuel Sámano Ortega”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels