Conference abstract · 15 Sep 2015
Conference abstractPublished 24 Aug 2015
CT scan – Automatic tube current modulation
Apollo Health Street, India
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
AIM OF THE STUDY: To compare the dose difference and state the significance of Automatic Tube Current Modulation (ATCM) in abdominal MDCT examination while maintaining optimum image quality for diagnosis. Results: The varying in MAS values according to ACS for different body counter of the patients was observed. In group A resulted in estimations of dose saving in range of 10-27 %.In group B 8.1-36.6 %, in group C 8.3-33.4%, group D 5.7-19 % with application of ATCM technique. The overall radiation output results shown for forty patients as follows the least is 5.7% and highest is 36.6%.According my study statistics shows there is no correlation between BMI and the estimated dose savings. • Radiation Dose reduction Up to 36.6% was achieved with acceptable diagnostic image quality. • Reduces over all irradiation time. • Helps in reduce stochastic and genetic effects. • Helps in Not only reduce the patient dose as well as occupational dose. • Scan duration is less compare to standard protocol so we can save the time at clinical side. • Effective in breath hold scans (Coronary Angio, Pulmonary Angio, Thorax and Abdomen). • Required dose is applied according to patient body counter. • Helps in decrease scan time in uncooperative and trauma patients. • I conclude that according to the observed results. Aim of the study To compare the dose difference and state the significance of Automatic Tube Current Modulation (ATCM) in abdominal MDCT examination while maintaining optimum image quality for diagnosis. Conclussion The use of Automatic Tube Current Modulation (angular dose modulation and z-axis dose modulation) helps in
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 18 Mar 2019
Assessment of automatic tube current modulation technique of multi detectors computed tomography machine in multiphasic examinations computed analysis
Research article · 31 May 2021
Assessment of radiation dose reduction potential and clinical utilization of automatic tube current systems
Commentary · 28 Mar 2023
Automatically Tumor Recognition using Histopathological Tissue Scans
Research article · 24 Nov 2021
Assessment of the Knowledge of CT scanner Operators on the Use of Dose Reduction Software Called Automatic Exposure Control (AEC) During a CT scan
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “N. Purna Chander Reddy”
