Research article · 2019
Conference abstractPublished 28 Nov 2016
Automatic conversion of PSCAD data into ESP format
eMIT, LLC, USA
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
China Southern Power Grid (CSG)has become the world's largest and most complex AC and DC hybrid power grid. The CSG is very complex due to HVDC, FACTS, and other high-voltage power electronic equipment operating characteristics and control strategies. Growing environmental concerns and continuing efforts to reduce dependency on fossil fuel energy resources are bringing renewable energy resources to the generation portfolio of CSG. Among the various renewable resources, wind and solar power are assumed to have the most favorable technical and economic prospects. To be effective, integration of wind and solar energy in power system operations requires a comprehensive approach to simulate the electromagnetic process in great details. The power electronic devices also greatly influence the dynamic characteristics of the grid. With the continuous advancement in power electronics, the increasing number of HVDC and renewable generations that are being built within CSG’s footprint, the need for accurate and intuitive simulation tools becomes more and more important at CSG. CSG developed an Electromagnetic Simulation Program (ESP) which includes an electromagnetic- transient hybrid simulation interface. ESP is able to complete the electromagnetic transient simulation for large scale AC and DC system with large penetration of renewable energy with fast speed and high accuracy. While ESP was being developed, CSG used PSCAD (Power Systems Computer Aided Design) to simulate electromagnetic transients and built all the models using PSCAD. This required tremendous effort. During the course of ESP development, in order to utilize all of the modeling effort asscoiated with PSCAD, an automatic conversion program (ESPCVT) was developed to automatically convert most of the PSCAD transmission model into the ESP model. The most difficult challenge of the conversion is that the PSCAD model is graphically based and the topology information of all elements is realized via the closeness of the coordinates of the element. This paper describes the PSCAD modeling methodology, how to map the PSCAD model into the ESP model, and all the conversion details. This automatic process eliminates the human errors occurring when the data is converted manually. ESPCVT was tested successfully on several systems including a real CSG electromagnetic simulation system of 1390 network nodes and 5133 network branches. Using the converted data, ESP’s simulation results agree with what is obtained using PSCAD.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2016
Bioaerosol Formation and Bacterial Transfer from Commercial Automatic Hand Dryers
Conference abstract · 17 Jun 2013
Conversion of carbon dioxide into methane formation by methane-producing bacterium FJ10 under pressurized conditions
Research article · 2012
Glucose conversion to 5-hydroxymethylfurfural- pH enhanced product formation using CrCl2 in liquid water
Short communication · 1996
Microbial Conversion & Formation Studies On The Secondary Metabolites Of Solanum Xanthocarpum (Schrad And Wendle)
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “Chaoyang Jing”