Research article · 18 Mar 2019
Conference abstractPublished 2015
CT scan – Automatic tube current modulation
Apollo Health Street, India Manipal University, India Nitte University, Mangalore
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
AIM OF THE STUDY: To compare the dose difference and state the significance of Automatic Tube Current Modulation (ATCM) in abdominal MDCT examination while maintaining optimum image quality for diagnosis. Results: The varying in MAS values according to ACS for different body counter of the patients was observed. In group A resulted in estimations of dose saving in range of 10-27 %.In group B 8.1-36.6 %, in group C 8.3-33.4%, group D 5.7-19 % with application of ATCM technique. The overall radiation output results shown for forty patients as follows the least is 5.7% and highest is 36.6%. According my study statistics shows there is no correlation between BMI and the estimated dose savings. • Radiation Dose reduction Up to 36.6% was achieved with acceptable diagnostic image quality. • Reduces over all irradiation time. • Helps in reduce stochastic and genetic effects. • Helps in Not only reduce the patient dose as well as occupational dose. • Scan duration is less compare to standard protocol so we can save the time at clinical side. • Effective in breath hold scans (Coronary Angio, Pulmonary Angio, Thorax and Abdomen). • Required dose is applied according to patient body counter. • Helps in decrease scan time in uncooperative and trauma patients. • I conclude that according to the observed results. Aim of the study: To compare the dose difference and state the significance of Automatic Tube Current Modulation (ATCM) in abdominal MDCT examination while maintaining optimum image quality for diagnosis. Conclussion: The use of Automatic Tube Current Modulation (angular dose modulation and z-axis dose modulation) helps in
Subjects
Pathology & Lab MedicineAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 15 Sep 2015
CT scan âÂ?Â? Automatic tube current modulation
Commentary · 28 Mar 2023
Automatically Tumor Recognition using Histopathological Tissue Scans
Conference abstract · 5 May 2014
Evaluation of whole blood viscosity and hematological data using scanning capillary tube viscometer in pigs
Research article · 2014
Single-Tube Mutation Scanning of the Epidermal Growth Factor Receptor Gene using Multiplex LATE-PCR and Lights-On/Lights-Off Probes
More from this journal
The newest in Journal of Diagnostic Techniques and Biomedical Analysis.
Review article · 9 Aug 2024
Breast Cancer Diagnostics: Molecular Approaches
Opinion · 29 Dec 2023
Molecular Diagnostics: Decoding Disease at the Genetic Level
Opinion · 29 Dec 2023
From Data Streams to Diagnoses: AI's Journey in Healthcare
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Diagnostic Techniques and Biomedical Analysis
- SubjectPathology & Lab Medicine
- BylineArticles whose byline prints “Nimma Purna Chander Reddy”
- BylineArticles whose byline prints “Suresh Sukumar”
- BylineArticles whose byline prints “Sushil Yadav”
- BylineArticles whose byline prints “Albin Babu M Wilson”