Background: Ventricular Septal Defect (VSD) is the commonest congenital cardiac anomaly in Bangladesh. For this reason, patch repair of VSD is a commonly performed cardiac surgery here. Aim: The aim of the study is to observe the short-term outcome of patch repair of VSD. Methods: 50 consecutive patients were enrolled in the study by purposive sampling who received treatment for isolated VSD in Department of Pediatric Cardiac Surgery of Dhaka Shishu (Children) Hospital, Dhaka, Bangladesh. They underwent VSD patch repair from January 2017 to December 2017. A prospective observational cross-sectional study was conducted for this 12 months period. A pre-structured, interview and observation based, peer reviewed data collection sheet was prepared. Data regarding sociodemographic, clinical, surgical and outcome profile were recorded. Data were compiled, edited and analyzed with SPSS version 23. Data were presented as mean and standard deviation, frequency percentage and median with range. Results: The mean birth weight of 50 patients was 2.8 kg (range: 2.1 âÂ?Â? 3.5 kg) whereas the median of gestational age was 38 weeks. Among these 50 patients, 22 (44%) and 28 (56%) were boys and girls respectively. The only indication of surgery was volume load. Out of 50 patients, 46 (92%) had peri membranous variety. On the contrary, 4 (8%) experienced Double committed type of VSD. The mean Bypass time and Aortic cross-clamp time were recorded as 70Ã?±13.7 minutes and 35Ã?±6.85 minutes respectively. Out of 50 patients who underwent PTFE patch repair, 2 (4%) experienced pneumothorax, 1 (2%) got chylothorax and 1 (2%) had transient heart block. Total 45 (90%) patients showed uneventful outcome. Conclusion: Contemporary results of PTFE patch repair in case of VSD showed unparallel outcome with extremely low morbidity in our perspective.

Subjects

Cardiology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Clinical and Experimental Cardiology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalClinical and Experimental Cardiology
  • SubjectCardiology
  • BylineArticles whose byline prints “Kazi Zahidul Hoque”
  • BylineArticles whose byline prints “Mamun Miah”
  • BylineArticles whose byline prints “Makbul Hossein”
  • BylineArticles whose byline prints “Ashik Imon”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels