Conference abstract · 26 Oct 2013
Conference abstractPublished 28 Sep 2016
Extractive Electrospray Ionization Mass Spectrometry For Biosample Analysis
Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, China
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Mass spectrometry (MS) is one of the preferable analytical techniques for sensitive characterization of biological samples on the molecular levels. Technological innovations advance mass spectrometry for sophisticate applications in many fields including but not limited to chemistry, material sciences and life sciences. For trace analysis of a typical biological sample, classical MS techniques require multi-step sample pre-treatment (e.g., grinding, extraction, separation, pre-concentration, etc.) to obtain molecular information from the native biological samples, especially for detection of trace analytes distributed in the 3-dimensional volume of a bulk sample[1,2]. Commonly associated with sample pre-treatment are biological degradation, chemical reactions, reagent contamination, and material losses. Apparently, tedious sample pretreatments strangle the breakthrough of high throughput in analytical mass spectrometry. By isolating the high electric filed required for ionization from any biological sample, extractive electrospray ionization (EESI) allows direct detection of small metabolites and/or large proteins distributed either on surfaces or inside bulk tissue by mass spectrometry, without any sample pretreatment. Experiments demonstrated that EESI-MS minimizes matrix effects during the ionization process, enabling real-time, in vivo analysis of biofluids, biosurfaces, aerosols and living objectives. Therein the fundamental principle, instrumentation and typical applications of EESI-MS for biological analysis would be summarized, giving emphases on progresses in our lab for sensitive qualitative/quantitative detection of chemicals located inside a bulk tissue of whole-volume (≥20 mm3), with neither mashing/grinding the sample nor matrixes clean-up[3-5]. Furthermore, the emerging utilization of EESI-MS for sequentially acquiring metabolites, lipids, and proteins in a single tissue sample will be presented for the first time.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 15 Jun 2022
Phytochemical Analysis of Acacia auriculiformis Pericarp through Liquid Chromatography-Electrospray Ionization-Mass Spectrometry
Conference abstract · 2018
Analysis of oligonucleotides by ion-pair hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry (IP-HILIC/ESIMS)
Conference abstract · 19 Jun 2017
Analysis of oligonucleotides by ion-pair hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry
Research article · 2016
Characteristic Fingerprint Analysis of Mallotus philippinensis by Ultra Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “Huanwen Chen”
