Research article · 2013
Conference abstractPublished 11 Dec 2017
Novel MRI safe mode selection algorithm: A standardized real-time solution for a variable time-dependent problem
Boca Raton Regional Hospital, Florida Atlantic University, USA
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Statement of the Problem: MRI scans in patients with cardiac MRI conditional devices (pacemakers and ICDs) are exponentially growing. All devices require pre-scan interrogation and accordingly reprograming to an MRI safe mode. Today there is no medical or industry guideline about how to program an MRI safe mode. The performance of this task is for the most part done by a field company representative whom should follow a âÂ?Â?Cardiology OrderâÂ? form. This workflow, across the US, is difficult to follow in its conceived fashion having significant limitations and compliance issues. Additionally, when the decision on safe mode is not done upon the scan performance, depending on the time interval the patient’s condition may have changed. Methodology & Theoretical Orientation: In order to simplify the decision-making process and streamline the service model a proprietary algorithm was conceived to provide an answer in real time to the most appropriate MRI safe mode programming upon performing the scan. The algorithm was used in 11 MRI centers and applied to a total of 246 cardiac devices, from 4 different companies 232 Pacemakers (223 DDD/9 VVI); 14 ICDs (10 DDD/4 VVI). Sinus rhythm was the most common presenting underlying rhythm 93% and AF 7%. Most common presenting modes were: DDD 116, AAI-DDD 84, VVI 12, rate response was on in 50%. The most common MRI safe mode programmed were DOO 36%, followed by AOO 31%. In no instance, a patient’s device interrogation wouldn’t fit the algorithm. There were no complications. Conclusion & Significance: The clinical validation of the MRI safe mode selection using the MK-ALGORITHMÃ?© provides a standardize solution, that streamlines patient care, meant to be a resource for orders not only by the specialists but by other physicians involved in the patient care such as radiologists onsite at the MRI center performing the scan.
Subjects
CardiologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Commentary · 18 Dec 2017
Magnitude of Time-Dependence of Beat-to-Beat Muscle Blood Flow Between Isometric Contraction and Relaxation During Repeated Knee Extensor Exercise at Incremental Workload
Opinion · 28 Jan 2025
Towards Real-Time Neurofeedback Using Functional MRI: Algorithms and Applications
Perspective · 29 Jul 2025
AI Real-Time Plaque Elasticity for Fluoroless Angioplasty
Article · 30 Jan 2025
Design and Development of a Real-time Wearable Cardiac Monitoring System
More from this journal
The newest in Clinical and Experimental Cardiology.
Short communication · 4 Aug 2026
An effective determination method for aortic valve replacement through minimally invasive lower median sternotomy
Conference abstract · 15 Jun 2026
Speckle Tracking Echocardiography for Early Identification of Chemotherapy-Induced Cardiotoxicity
Conference abstract · 15 Jun 2026
Coronary CT Angiography as a First-Line Diagnostic Tool for Stable Chest Pain: Clinical Outcomes from a Multicenter Study
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalClinical and Experimental Cardiology
- SubjectCardiology
- BylineArticles whose byline prints “Esteban Martin Kloosterman”