Introduction: The gold standard device for intraocular measurement is the Goldmann Applanation tonometer. A number of factors can influence its measurements including the amount of fluorescein inserted, corneal thickness, astigmatic error and pressure on the globe. Errors of precision can be minimised by adjusting for these factors in examination or calculation. However, a step that is often omitted is calibration of the tonometer. No current UK guideline for tonometer calibration exists. Haag Streit suggest +/-0.5mmHg as an acceptable calibration error. Method: The method outlined by the manufacture of Haag-Streit was implemented to assess the calibration of 11 Goldmann tonometers in the department. The dial was turned clockwise for the first measurement and anti-clockwise for the second measurement. Readings were averaged. Tonometers that were not calibrated within +/-1mmHg or due for service were returned to the manufacture. Tonometer calibration was re-audited one month later. Results: 11 tonometers in the outpatient department were audited. 45% of Goldmann applanation tonometers were calibrated within limits of +/-1mmHg. Calibration error ranged between 0 to 8mmHg. 6 tonometers were sent back to Haag Streit for re-calibration and servicing. One month later callibration was reassessed. Conclusion: All Goldmann applanation tonometers in the outpatient department are now calibrated within limits of +/1mmHg. A proforma was introduced to be filled in on a monthly basis. Each Goldmann tonometer lying outside calibration limits will be sent to the manufacturer for servicing and recalibration. It is clear from this audit that the responsibility for tonometer calibration checks needs to be defined but will depend on local guidelines and acceptable calibration error. This audit demonstrates how important calibration is, and without this, how variable the measurements can be thus influencing our medical decisions. Without this being specified as part of routine equipment maintenance, its importance may be overlooked.
Subjects
Ophthalmology & OptometryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 17 Aug 2022
Utility of Optic Nerve Sheath Diameter Measurement by Point of Care Ultrasound to Detect Raised Intracranial Pressure: A Prospective Observational Study
Conference abstract · 16 Feb 2022
Mouth opening, jaw disability, neck disability, pressure pain thresholds and myofascial trigger points in patients with disc displacement with reduction
Research article · 8 Nov 2020
Human pressure threaten Swayne's Hartebeest to point of local extinction from the Savannah Plains of Nech Sar National Park, South Rift Valley, Ethiopia
Research article · 23 Apr 2020
Effect of Pressure Release and Positional Release with Phonophoresis in Management of Myofascial Trigger Point of Trapezius
More from this journal
The newest in Journal of Clinical and Experimental Ophthalmology.
Research article · 6 Oct 2026
Visual performance of wavefront-shaping extended-depth-of-focus intraocular lenses in Japanese eyes after previous laser in situ keratomileusis
Short communication · 30 Aug 2026
Vision Science in the Modern Era: Integrating Neuroscience, Genetics, and Technology
Commentary · 3 Aug 2026
Emerging Frontiers in Experimental Ophthalmology: Innovations and Translational Challenges
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Clinical and Experimental Ophthalmology
- SubjectOphthalmology & Optometry
- BylineArticles whose byline prints “Anika Nanda”
- BylineArticles whose byline prints “Susan Downes”