In Western societies the steady increase in human life expectancy is posing a significant socioeconomic challenge to maintain existing medical therapy standards and health care solutions for senior patients. It is also well known that elderly patients exhibit a significantly higher risk of complications following surgery. To prevent postoperative and long-term medical complications, an important strategy of medical traumatology involves repeated follow-up examinations using a variety of in vivo imaging technologies and in vitro assessment methods of biopsies. To improve early diagnosis of failed implant integration and tissue rejection, we have developed two implantable titanium dioxide-coated bioimpedance sensors to enable personalized therapeutic interventions during (1) impaired bone healing and (2) organ transplant rejection. (1) In the case of endosseous implants, which are routinely applied in tissue reconstruction after long bone, spine and craniomaxillofacial injuries, the development of a prognostic non-invasive imaging technology capable of monitoring dynamic bone formation in situ is expected to deepen our understanding of osseous integration at the implant-tissue biointerface. Results of our study revealed distinct differences between granulation and soft tissue formation within two weeks after implantation, thus allowing the accurate assessment of bone healing prior the formation of a cortical bone layer in subcritical defects of rabbit calvaria. (2) Every transplanted tissue and solid organ bears the risk of rejection, which can finally result in the loss of the transplant with falling back into disability or even death. Tissue biopsies are used today to detect and monitor tissue or solid organ rejection episodes. Detection of early stages of rejection and continuous monitoring can therefore prevent severe organ impairment or even loss of function. To overcome limitations of the state of the art rejection monitoring methods, we have developed titanium-dioxide coated implantable biosensors for transplant rejection monitoring.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels