Scholars Central

Conference abstractPublished 10 Aug 2017

Progress and applications of biometry

Authors: Jinhai Huang

Wenzhou Medical University, China

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Accurate obtainment of parameters of the eyeball is crucial in both clinic and research. Main parameters include central corneal thickness, anterior chamber depth, axial length, keratometry, lens thickness, white to white, pupil diameter and so on. For example, central corneal thickness is critical laser in situ keratomileusis and glaucoma diagnosis, intraocular lens calculation. The topography was an essential method to evaluate the cornea shape and cornea disease just like keratoconus. Ultrasound was the main method to acquire most of those parameters for years and it was thought as a golden standard. The first optical biometer, the IOLMaster basing on partial coherence interferometry was introduced in 1999. The optical method had shown excellent repeatability and reproducibility in clinic and the accuracy had been confirmed in many studies. Since 2009, several optical biometers are available including the Lenstar, the Aladdin, the AL-Scan, the OA-1000, the Galilei G and the Pentacam AXL. The Lenstar which is based on optical low-coherence reflectometry is another widely used optical biometer comparable to the IOLMaster. Placido’s disk is a widely used technique to provide topography but it is unable to show the posterior surface of cornea. The Orbscan corneal topography system which is an optical-based, slit scanning instrument is the first one which can measures three-space points on the anterior and posterior corneal surfaces. However, it was gradually replaced by the Pentacam using Scheimpflug principle which showed higher repeatability, reproducibility and agreement with Placido. After that, Sirius which combines Placido and Scheimpflug shows its reliability in some studies. More recently, the OA-2000, the IOLMaster 700, the Argos which mainly based on swept-source optical coherence tomography are introduced for dense cataract.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Clinical and Experimental Ophthalmology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Experimental Ophthalmology
  • SubjectOphthalmology & Optometry
  • BylineArticles whose byline prints “Jinhai Huang”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels