Scholars Central

Conference abstractPublished 10 Aug 2017

Comparison of swept-source optical coherence tomographer (SS-OCT) and partial coherence interferometry (PCI): Ocular biometry and repeatability

Authors: Choun-ki Joo, Mihyun Choi, Minji Kang, Jihye Lee, Youngju Ahn, Woong-Joo Whang, Young-sik Yoo

Catholic University of Korea, South Korea

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Introduction & Aim: The third-generation formulas require the information of the anterior corneal power (K) or the anterior corneal radius of curvature (R) as measured by keratometry and of the axial length (AL) as measured by biometry. This study aims to evaluate the repeatability of the SS-OCT measurements (Argos, Movu, Inc.) and to compare the AL, anterior chamber depth (ACD) and K measurements with the results obtained with the PCI (IOLMaster, Ziess, Germany). Methods: The retrospective, cross-sectional study was done between September 2016 and October 2016. In 65 patients with planned cataract surgery, the following were measured using both methods; visual acuity, auto-refraction, manifest-refraction, keratometry (D), AL (mm) and ACD (mm). Each measurement was measured three times; the comparison between the two groups and between 3 measurements in one individual was done. Results: The mean difference between the two groups was 0.06Ã?±0.009 mm in AL (p=0.539), 0.14Ã?±0.019 D in Keratometry (p=0.134) and 0.20Ã?±0.021 mm in ACD (p=0.121). There was no significant difference between the two groups. The intraclass correlation coefficient of SS-OCT was 1.000 in AL, 0.999 in keratometry and 0.996 in ACD, respectively. Conclusions: The measurements of SS-OCT ocular biometer (Argos, Movu, Inc.) were not significantly different from those of the PCI device (IOLMaster). Measurements with the SS-OCT biometer were repeatable.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Journal of Clinical and Experimental Ophthalmology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Experimental Ophthalmology
  • SubjectOphthalmology & Optometry
  • BylineArticles whose byline prints “Choun-ki Joo”
  • BylineArticles whose byline prints “Mihyun Choi”
  • BylineArticles whose byline prints “Minji Kang”
  • BylineArticles whose byline prints “Jihye Lee”
  • BylineArticles whose byline prints “Youngju Ahn”
  • BylineArticles whose byline prints “Woong-Joo Whang”
  • BylineArticles whose byline prints “Young-sik Yoo”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels