Scholars Central

Conference abstractPublished 29 Apr 2019

Fast phage detection and quantification: An optical density-based approach

Authors: Denis Rajnovic

University of Barcelona, Spain

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Since 1959 with the proposal of Double Agar Layer (DAL) method for phage detection and quantification, many sophisticated methods have emerged meanwhile. However, many of them are either too complex/expensive or insensitive to replace routine utilization of DAL method in clinical, environmental and industrial environments. For that purpose, we have explored an alternative method for the detection and quantification of bacteriophages that fulfills the criteria of being rapid, simple and inexpensive. In this paper we have developed a method based on the analysis of optical density kinetics in bacterial cultures exposed to phage-containing samples. Although the decrease in optical density caused by cell lysis was one of the first observable consequences of the effect of viral infection in bacterial cultures, the potential of the method for the assessment of phage abundance has never been fully exploited. In this work we carry out a detailed study of optical density kinetics in phage-infected bacterial cultures, as a function of both, phage abundance and initial concentration of the host organisms. In total, 90 different combinations of bacteria/phage concentrations have been used. The data obtained provide valuable information about sensitivity ranges, duration of the assay, percentages of inhibition and type of lysing behavior for each phage concentration. The method described can detect, as few as 10 phage particles per assay volume after a phage incubation period of 3.5h. The duration of the assay can be shortened to 45 min at the expense of losing sensitivity and increasing the limit of detection to 108 pfu/ml. Despite using non-sophisticated technology, the method described has shown sensitivity and response time comparable to other high-end methods. The simplicity of the technology and of the analytical steps involved, make the system susceptible of miniaturization and automation for high-throughput applications which can be implemented in routine analysis in many environments.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

Conference abstract · 28 Nov 2016

Generation of high power pulses with high repetition rate with subnanosecond pulse front for pumping different lasers Peter A Bokhan, A V Rzhanov Institute of Semiconductor Physics, Russia Session Discussion Sessions On Applications and Trends in Optics | Quantum Science and Technology Session Introduction Session Chair: Luis Gustavo Marcassa, University of São Paulo, Brazil Session Co-Chair: Zhe Wang, Tsinghua University, China 14:45-15:05 Title: Detection of diseases in citrus plants using fluorescence spectroscopy Luis Gustavo Marcassa, University of São Paulo, Brazil 15:05-15:25 Title: Optical phased array propagation in atmospheric channels and coherent beam combining Itay Naeh, Tel Aviv University, Israel 15:25-15:45 Title: Laser beam shaping by manipulating spatial coherence Milo W Hyde IV, Air Force Institute of Technology, USA 15:45-16:05 Title: Laser terahertz emission microscope Masayoshi Tonouchi, Osaka University, Japan Networking & Refreshment Break 16:05-16:25 16:25-16:45 Title: LIBS in China and its quantification development laser-induced breakdown spectroscopy Zhe Wang, Tsinghua University, China 16:45-17:05 Title

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • BylineArticles whose byline prints “Denis Rajnovic”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels