CON4EI: Consortium for in vitro eye irritation testing strategy

Authors: An R Van Rompay, Els Adriaens, Nathalie Alepee, Helena Kandarova, Przemyslaw Fochtman, Robert Guest, Jamin A Willoughby, Sandra Verstraelen

Flemish Institute for Technological Research, Belgium; Adriaens Consulting BVBA, Belgium; LâÂ?Â?OrÃ?©al Research and Innovation, France; MatTek In Vitro Life Sciences Laboratories, Slovakia; Institute of Industrial Organic Chemistry Branch Pszczyna, Poland; Envigo, UK; Cyprotex, USA

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Measurement of ocular irritancy is a necessary step in the safety evaluation of industrial and consumer products. Assessment of the acute eye irritation potential is therefore part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project is to identify strategic combinations of alternative test methods within a tiered-testing strategy in order to replace the in vivo Draize eye test. Therefore, a set of 80 reference chemicals covering the most important in vivo drivers of classification, balanced according to the physical form (38 liquids and 42 solids) and representing different chemical classes, was tested in eight in vitro test methods. The set was composed of 15 chemicals not requiring classification (No Cat) and 65 chemicals requiring classification (27 Cat 2 and 38 Cat 1). The performance with regard to the in vivo drivers of classification of the following methods was evaluated individually: BCOP and BCOP-LLBO, ICE, EpiOcular EIT, EpiOcular ET-50, HCE EIT, STE and SMI test method. In a second step, two by two agreement between test methods was evaluated to identify similarities between methods. Finally, different test methods were combined into a testing strategy and the performance was evaluated. These analyses provided evidence that different testing strategies are possible. For example, a combination of the BCOP and HCE EIT test method resulted in an accuracy of 81% with a Cat 1 sensitivity of 86.3%, Cat 2 sensitivity of 63% and 100% specificity. Furthermore, none of the Cat 1 chemicals were identified as No Cat. This was an improvement over the stand alone assays that cannot differentiate between the different categories. Similar results were obtained when the BCOP was combined with HCE EIT or EpiOcular EIT.

Subjects

Toxicology

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Clinical Toxicology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical Toxicology
  • SubjectToxicology
  • BylineArticles whose byline prints “An R Van Rompay”
  • BylineArticles whose byline prints “Els Adriaens”
  • BylineArticles whose byline prints “Nathalie Alepee”
  • BylineArticles whose byline prints “Helena Kandarova”
  • BylineArticles whose byline prints “Przemyslaw Fochtman”
  • BylineArticles whose byline prints “Robert Guest”
  • BylineArticles whose byline prints “Jamin A Willoughby”
  • BylineArticles whose byline prints “Sandra Verstraelen”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels