Metrological Assessment of Infrared Tympanic Thermometers: A Safety Measure
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: There are different temperature readings in different body sites that are estimated values of the core temperature. The IR tympanic thermometers measure the thermal radiation of the tympanic membrane. These devices are often considered the best non-invasive and most accurate technique to measure body temperature. The incorrect use and the features of the IR tympanic thermometers may lead to significant errors in temperature readings. A metrological approach allows the analysis of the accuracy of the IR tympanic thermometers when compared to a standard electronic device. The main purpose of this study was to assess the measuring errors of the infrared (IR) tympanic thermometers over time and to decide the best time interval between metrological assessments. Methods: The metrological control of IR tympanic thermometers (n=125 used in adult and n=21 in paediatric patients) was based on the comparison with a thermal imaging black body device. An acceptance criterion (AC) of ±0.2°C was considered for metrological control. Results: 93.90% of the errors of low temperature readings (32°C) and 94.24% of the errors of high temperature readings (40°C) were within the acceptance criterion (±0,2°C). Results show 6% of the errors out of specifications. The maximum and minimum errors were +2.5°C and –0.8°C and +0.8°C and -5.2°C for low and high temperatures, respectively. For high temperatures the errors decrease gradually over time unlike to the observed regarding the low temperatures. Conclusions: The variability of errors might be device related; nevertheless it does not preclude its reliability. Significant errors were not found. The accuracy of the IR tympanic thermometers improved over time for high temperatures. Regular metrological assessments are needed to identify errors and assure a good performance of the IR tympanic thermometers.
Keywords
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 15 Aug 2016
In adult patients the effect that auricle s position has on the body s temperature measurement values during measurements performed through tympanic membrane thermometer
Research article · 2018
In-vivo Corneal Temperature during Cross-linking Measured by an Infrared Thermometer
Research article · 12 Mar 2024
Calibration Method of Clinical Type Infrared Thermometers and Estimation Uncertainty in Different Blackbody Cavities
Short communication · 20 Mar 2023
Assessing the Safety and Efficacy of Vaginal Birth After Cesarean (VBAC) in Low-Risk Pregnancies
More from this journal
The newest in Journal of Pregnancy and Child Health.
Research article · 31 Jul 2026
Hospital and Doula Care Integration in the Obstetric Setting: A Qualitative Study
Editorial · 22 Jul 2026
Nurturing Development: Key Factors For Child Well-being
Editorial · 20 Jul 2026
Foundations of Healthy Infant Development: A Holistic Approach
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Pregnancy and Child Health
- SubjectPaediatrics & Neonatology
- SubjectReproductive Medicine & Gynaecology
- BylineArticles whose byline prints “Ana Luisa Silva”
- BylineArticles whose byline prints “Cláudia Pereira”
- BylineArticles whose byline prints “Sílvia Moutinho”
- BylineArticles whose byline prints “Cecilia Rodrigues”
- BylineArticles whose byline prints “Humberto S Machado”
- BylineArticles whose byline prints “Idalina Beirao”