Brief report · 29 Sep 2025
Conference abstractPublished 9 Nov 2017
Steel structure optimization through the performance based design: Case study using push over analysis
The Open University of Sri Lanka, Sri Lanka
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Steel structures became fastest and attractive construction strategy for the industrial building all over the world form the two decades ago. However, the many countries followed their own codes to design the steel structures based on experience. However, most of the design has been done based on the local design philosophy and country accepted codal provision given. In this research it has been discussed the performance based design of steel building to predict the global behavior in order to optimize the steel structures over the global behavior. The two case studies have been done to evaluate the structural performance of the steel structures. The both studies have been carried out under the same loading (lateral) and output compared by using push over analysis. Elastic spectrums have been derived and it has compared with demand curve produced. However, local structural elements also be evaluated based on the codal provision given in order to make sure the ultimate and serviceability limit state. It clearly show that convectional design proceedings for the steel structures has been shown less performance compare to performance based design. The performance based analysis were compared and show significant impact on the design phase where the critical analysis of the structure became the lateral loading condition. The plastic hinge formation of structure used to predict the overall structural performance. Finally, it has been compared foundation, super structural element separately for the purpose of doing the cost comparison. In Sri Lanka, the most of the construction are focus to reinforced concrete and however most of the client brings realizing the advantages of steel structure. Only challenge is the structural stability over the ductility which earns more on concrete. But, it has been addressed over this design for moderate condition where the Euro code 8 specified respect to the Ecurocode 3 (steel design). The loading combinations of each structure have been considered as per the BS 6399 and it is more conventional to have lateral loading condition.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Opinion · 30 Jun 2025
Steel Plate Girder Design: Analysis, Optimization, Performance
Research article · 2017
Performance Base Design of Multi-Storey Steel Structures Considering Dynamic Loads Originated by Geological Agents
Conference abstract · 16 Nov 2015
Performance based design of cold formed steel structures
Conference abstract · 8 Sep 2014
Design and process optimization of a push a button and walk away microwave based green extraction technique for naturally occurring bioactive compounds