Case report · 9 Nov 2022
Conference abstractPublished 22 Oct 2018
Virtual Reality Image Analysis in Aortic Valve Leaflet Reconstruction
Ageo Central General Hospital, Japan
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Aortic valve reconstruction with three same-sized autologous pericardial leaflets has been performed for patients with narrow aortic roots or contraindication for valve-prostheses. Since this procedure requires precise information of the aortic root including configuration of Valsalva sinus, we assessed physiologic-anatomical condition of the aortic root by Virtual Reality (VR) Image in order to accomplish this technique with a reproducible fashion. VR Imaging; Enrolled patients underwent enhanced ECG-triggered cardiac CT. Axial images using a 264-row CT with slice thickness of 0.625mm were obtained during mid-to-end diastole. Subtracted volume rendering data of the aortic root were converted to stereolithography (STL) file in Visalius3D, a novel 3D workstation. Preoperatively the aortic root was assessed in order to decide neo-commissure and offsetting of deviated nadir in cases of unbalanced aortic root, like type 0 bicuspid valve. Basic surgical technique was; 1) same-sized three pieces of leaflets from autologous pericardium were tailored to original templates referred by STJ diameter, 2) the new commissures and nadirs were confirmed based on VR image (in case the non-coronary nadir deviated toward the left ventricle, a crescent form Valsalva plication were required), 3) three leaflets were sutured on the cusp-sutureline, 4) commissure coaptation stitches were placed between each leaflet to prevent from minor leakage and coronary orifices obstruction. Postoperative echocardiography revealed nicely opening of new-leaflet with no AR. VR image analysis had notably provides valuable information for understanding of precise anatomy of the aortic root.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 18 Oct 2018
Development of a bioprinted 3D model of aortic valve leaflet seeded with human valvular interstitial and endothelial cells
Research article · 21 Oct 2017
Comparison of Cormatrix® porcine extracellular matrix and pericardial patch augmentation for tricuspid valve leaflet reconstruction - A singlecenter experience.
Case report · 27 Jan 2025
Reconstruction of the aortic root with preservation of the aortic valve (case from practice).
Conference abstract · 10 Jul 2017
Acute dissection of ascending aorta : Early experience of emergency, valve sparing aortic root reconstruction
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “Takeo Tedoriya”
