Conference abstract · 19 Oct 2017
Conference abstractPublished 19 Oct 2017
A diatomic chain with a mass impurity
Nevada, USA
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
It has a long history to study monatomic and diatomic chains with or without impurity as models for dynamics of lattices. By means of recurrence relations method, a diatomic chain with an impurity is studied. The Laplace transform of the momentum autocorrelation function of the impurity is derived. It has two pairs of resonant pole and three separated branch cuts. The poles lead to cosine function(s) and the cuts result in acoustic and optical branches. A frequency theorem is derived governing the upper and lower frequencies of the two branches; Criteria for resonant poles are established; general expres-sions for frequency and amplitude of cosine(s) are derived. The acoustic and optical branches can be expressed as inverse Laplace trans-forms which are not easy to be carried out in general. By means of convolu-tion theorem, analytical expressions for acoustic and optical branches are derived as expansions of even-order Bessel functions. The expansion coeffi-cients of the acoustic branch are integrals of real Jacobin elliptic functions. However, coefficients of the optical branch are integrals of complex elliptical functions. By addition theorem, the expansion coefficients for the optical branch are obtained as integrals of elliptic function along a contour parallel to the imaginary axis in a complex plane. A modulus theorem is derived relating the modulus of elliptic functions in the acoustic and optical branches.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 2018
A classic diatomic chain
Research article · 29 Nov 2022
Drug Development and Verification of Elemental Impurities Content in Cyclosporin Injection USP 250 mg/5 ml by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS)
Research article · 29 Nov 2022
Drug Development and Validation of Elemental Impurities Content in Methotrexate Injection USP 250 mg/10 ml by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS)
Research article · 31 Aug 2021
Development and Validation of an Inductively Coupled Plasma Mass Spectrometry Method for Estimation of Elemental Impurities in Calcium Acetate Active Pharmaceutical Ingredient
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- BylineArticles whose byline prints “Ming B Yu”