Scholars Central

Research articlePublished Jan 2021

Expandable Interbody Spacers Implanted Through a Lateral Approach: A Multicenter Observational Study at Two Years

Authors: Dan S Cohen, Richard Frisch, Joseph O'Brien, William Tally, Thomas K Lee, Torrey Shirk

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Introduction: Evidence surrounding use of expandable interbody devices during lateral lumbar interbody fusion (LLIF) has been sparse. While all LLIF devices purport to offer advantages such as avoidance of great vessels anteriorly and the spinal cord posteriorly, sufficient consensus among data for expandable devices is lacking, particularly among multiple surgeons who may have varied surgical correction goals with these devices. Objective: This study sought to describe outcomes of patients treated with expandable interbody spacers implanted through an LLIF approach. Methods: The current study’s patients were consecutively enrolled/ treated with one of two expandable interbody spacer designs by five surgeons at five sites, using a conventional transpsoas approach. Visual Analog Scale (VAS) back/leg pain scores, Oswestry Disability Index (ODI), and plain film radiographs were collected. Patients completed self-reported outcomes preoperatively and at 6, 12 weeks, 6, 12, and 24 months postoperative. Results: A total of 79 patients were enrolled across five study sites. Average age at time of surgery was 63 years (Range 33– 81). Average VAS lower back pain scores decreased significantly (p<0.001) from 6.7 (± 2.3) preoperatively to 2.9 (± 3.3) at 12 months and 2.9 (± 3.3) at 24 months. Average VAS leg pain scores decreased significantly (p<0.001) from 5.6 (± 2.8) preoperatively to 2.3 (± 2.6) at 12 months and 2.5 (± 2.9) at 24 months. Average ODI scores decreased significantly (p<0.001) from 45.9 (± 15.7) preoperatively to 25.0 (± 23.3) at 12 months and 26.2 (± 23.3) at 24 months. Disc height increased significantly (p<0.001) from 7.7 (± 2.6) preoperatively to 12.1 (± 2.8) at 12 months and 11.5 (± 2.4) at 24 months. There was no significant difference (p=0.091) in disc height between 12 and 24 months, suggesting a maintenance of disc height during this period. Conclusions: This multicenter, multi-surgeon study of two expandable lumbar interbody spacer designs demonstrates positive clinical and radiographic outcomes at 2 years.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Spine & Neurosurgery.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Spine & Neurosurgery
  • SubjectNeuroscience & Neurology
  • SubjectOrthopaedics
  • BylineArticles whose byline prints “Dan S Cohen”
  • BylineArticles whose byline prints “Richard Frisch”
  • BylineArticles whose byline prints “Joseph O'Brien”
  • BylineArticles whose byline prints “William Tally”
  • BylineArticles whose byline prints “Thomas K Lee”
  • BylineArticles whose byline prints “Torrey Shirk”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels