Scholars Central

Case reportPublished 31 Jan 2023

Troubleshooting sketchup Stokes problems using spectroscopic Stokes additional parameter based on the Fourier transform spectrometer partition method

Authors: Fernanda Cipriano

Journal of Experimental Stroke & Translational Medicine

Volume 15 · Issue 1 · Pages 09–11

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

[ 1 ]The Navier-Stokes (N-S) equations are solved in 3D incompressible viscous flow problems with and without through-flow boundaries using an alternate vector potential formulation. The application of boundary conditions for through-flow borders and the numerical treatment of fourth-order partial differential equations are challenging aspects of the vector potential formulation. On the other hand, benefits include decoupling pressure from velocity and automated fulfilment of the continuity equation. The purpose of this study is to introduce the proper gauge and boundary conditions to the localised meshless vector potential formulation. A Coulomb gauge condition is imposed on the vector potential to guarantee its existence and singularity analytically, handling the divergence-free quality. For measuring the spectroscopic Stokes parameters with a Fourier transform spectrometer, two approaches are suggested. [ 2 ]It is intended for single point measurement in the first approach. Using an optical set-up that includes a white light source, a polarizer set to 0, a quarter-wave plate, and a scanning Michelson interferometer, the parameters are recovered. The parameters for the suggested method are taken from the interferogram intensity distributions obtained with the quarter-wave plate rotated to 0°, 22.5°, 45°, and 45°, respectively. For the second strategy, a specific angle design in a polarizer and a quarter-wave plate can be used to create a full-field and dynamic measurement based on the first technique. Consequently, using a pixelated phaseretarder and polarizer, it is also possible to simultaneously extract the interferograms of two-dimensional detection. Based on a multi-channel analogue to digital converter and parallel read-out circuit with a high-speed CCD camera. As a result, a full-field, dynamic Stokes polarimetry without any spinning parts may be created. Both numerical and experimental evidence is presented to support the efficacy of the suggested strategies. According to the authors’ knowledge, this might be the most straightforward optical setup for obtaining the spectral Stokes parameters. It’s significant that the latter technique avoids the necessity for rotating optical system components and so offers a simple experimental method for obtaining the dynamic spectral Stokes parameters.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Experimental Stroke & Translational Medicine.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Experimental Stroke & Translational Medicine
  • SubjectNeuroscience & Neurology
  • BylineArticles whose byline prints “Fernanda Cipriano”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels