Scholars Central

ArticlePublished Feb 2017

Pena-Patel Technique; A Slight Modification could be Really Helpful

Authors: Wael MA Abdalla, Luis De La Torre

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Clinical Image: Pena-Patel technique [1] was introduced to help evaluate the relationship between the anal sphincter mechanism and the anus after pull through done for patients with anorectal malformation (ARM). The basic idea of the technique is to introduce a Foley catheter into the anal canal/rectum and marking the midline of the patient anteriorly and posteriorly using an IV line. MRI sequences are then obtained in axial, sagittal and coronal planes, preferably angled for best visualization of the pelvic floor muscles and sphincter mechanism. This techniques has proven to be very valuable in evaluating symmetry of the sphincter around the anus, degree of development of the sphincter muscles and additional evaluation for any pelvic associated abnormalities (e.g pelvic mass, presacral mass, sacral anomalies, spinal cord tethering). However, the study is done in the radiology department, most patient require sedation or General anesthesia, the limited time the radiologist get to spend with the patient physically, lack of muscle stimulators and the setting of the radiology department; all these factors do not allow the radiologist to have time or chance to examine the perineum and what actually ends up happening is placing a Foley catheter into the anus/rectum and marking the midline of the patient and patient is taking to the scanner and scanning begins. The images will be interpreted by the radiologist and all is done. This is a glimpse of our modern every day “Assembly line” model of work at big medical centers. We all get under the pressure of high volume of work, the need to stream work flow for scanners and the urge to keep the waiting list as short as possible. But this could cause errors in interpreting Pena-Patel technique MRI of some of our patients. Because in some of these patients the pull through went through a decent length of the sphincter mechanism and at its distal part happened to be located completely outside the sphincter, mostly posterior to the sphincter, probably to avoid coming too close to the scrotum. This will be found out during clinical examination and stimulation of the muscle of course. But the point here is to improve the outcome of Pena-Patel MRI examination. Hence we recommend marking the site of anal sphincter on the skin by a vitamin E ampule (Metallic markers cannot be used in MRI scanners) in addition to placing the Foley catheter through the rectum and marking the patient midline (Figure 1).

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in International Journal of Clinical & Medical Images.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalInternational Journal of Clinical & Medical Images
  • SubjectGeneral & Internal Medicine
  • BylineArticles whose byline prints “Wael MA Abdalla”
  • BylineArticles whose byline prints “Luis De La Torre”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels