Scholars Central

Conference abstractPublished 13 May 2019

Tunable-frequency two-dimensional wollaston prism-based structured illumination microscope

Authors: Ana Doblas, Sebastian Bedoya, Chrysanthe Preza

University of Memphis, USA

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Recently, we have shown that an axially-extended two-dimensional (2D) Structured Illumination (SI) pattern can be produced by a Fresnel biprism illuminated by a spherical wavefront emerging from one incoherent linear source1 (e.g. slit). This configuration provides a SI pattern equivalent to the one created by interfering two waves. The main advantage of using a Fresnel biprism illuminated by a slit (set at the front-focal plane of a conversing lens and the biprism is inserted between these two optical elements) is that the frequency of the SI pattern can be tuned by changing the axial position of the biprism with respect to the slit. In this work, we have experimentally validated a new incoherentbased tunable-frequency Structured Illumination Microscope (SIM) based on a Wollaston prism (WP)3 instead of the Fresnel Biprism (FB). The SI pattern in this new configuration is generated by splitting the light emerging from an incoherent slit using a WP. Our proof-of-concept results shows that the WP-based SIM system improves the lateral resolution of the native system along a single lateral direction as predicted by theory. Although this work was not aimed for a rigorous comparison between our WP-based and FBbased systems, during the studies reported here, we observed that the proposed WP-based SIM system presents some advantages over the optimal design of our FB-based 2D-SIM implementation. The first advantage (previously predicted by a theoretical study) is that the WP-based SI pattern has a higher lateral extension (i.e., the field of view with observable fringes is greater) and is not affected by any envelope function as in the case of the FB-based SI pattern. This means that data pre- or post-processing steps are not required in obtaining reconstructed SIM images without any undesired residual fringes. However, more importantly, a significant advantage of the WP-based SI device is that it can be used with a de Sénarmont compensator to produce a continuous and accurate phase shifting of the SI pattern. Using this phaseshifting method, the WP-based SI device can phaseshift the fringes by π rad for every 90 deg rotation of the analyzer regardless of the lateral modulation frequency of the pattern. This feature allows the acquisition of raw SIM images with proper phase shifting (i.e., different from π) at each lateral modulation frequency of the SI pattern without the need of recording additional phase-shifting calibration data. Finally, the double-shot processing method developed for our FB-based SIM1 to combine Optical-Sectioned (OS) and Super-Resolved (SR) 2D-SIM images can be used with the proposed WP-based SIM system to provide optically sectioned images with SR. Because of these advantages and the continuous variation of the SI pattern’s lateral modulation frequency up to the cutoff frequency of the system, we believe that the WP-based SI setup is suitable for an add-on SIM module that can be implemented in any commercial fluorescence microscope

Subjects

Chemistry

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Physical Chemistry & Biophysics.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Physical Chemistry & Biophysics
  • SubjectChemistry
  • BylineArticles whose byline prints “Ana Doblas”
  • BylineArticles whose byline prints “Sebastian Bedoya”
  • BylineArticles whose byline prints “Chrysanthe Preza”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels