Conference abstract · 2016
Conference abstractPublished 2016
Design-implementation procedure of impulse voltage generators
Eastern Mediterranean University, Turkey
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Power distribution and transmission devices can be exposed to voltage transients such as switching and lightning impulse voltages. Usually, impulse voltage withstand tests should be performed in order to reduce the risks of equipment failure. This raises the importance of generating high voltage impulses that make these tests conceivable. For each application, different type of testing waveform is required. These waveforms are defined by specific parameters including the duration, pulse width and raising time among others. Those parameters were partially standardized to organize and regulate different experimental data obtained from various investigations worldwide. In this study, the design aspects of a single-stage standard impulse voltage generator with desired voltage level and output waveform characteristics are detailed. The proposed approach maps the stated literature in [“An Introduction to High Voltage Engineering” by RAY S; “Impulse Testing of a Polluted Insulator with a Dc Bias Voltage” by Shifidi, S K et.al., and so on] into a permissible implementation, in which none of the used components has to be especially built for this purpose. That decreases both the implementation time and cost. Moreover, a verified example on the design of a mobile, low-cost 30 kV standard [1.2/50 μSec] lightning impulse voltage generator is implemented and tested. The validity of the design approach has been conducted both by experiments and simulations with the aid of the Pspice simulation environment in accordance with Kamarudin et.al. This study shows that, the usage of alternating high voltage input (HVAC) with voltage-multipliers that rectify and increase the voltage into a desired level of direct high voltage (HVDC) can be used to trigger a single-stage impulse generator circuit configuration. This approach can be considered as a solution of the accumulated inaccuracies of each stage of multi-stage impulse voltage generators. The overall work results in a mobile, easy to build, low-cost and accurate impulse generator that can eliminate the need of the high cost commercial impulse generator products.
Subjects
Energy & PowerAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Review article · Sep 2021
Implementing a Programmable Drop Voltage Controller Vlsi
Research article · 2015
Closed Loop Control of Zero Voltage Switching DC-DC Converter to Generate Three Outputs
Conference abstract · 2015
Second order sliding-mode for direct power control of doubly-fed induction generator under dips voltage
Research article · 2010
Design of Low Threshold Voltage AlGaN/GaN High Electron Mobility Transistors for High Power Switching and Digital Logic Applications
More from this journal
The newest in Journal of Nuclear Energy Science & Power Generation Technology.
Short communication · 24 Jul 2025
Short Communication on Advanced Thermal Circuits for Complex Thermal Management
Research article · 22 Apr 2025
Study of The Indian Energy Consumption in Context to the GDP Growth: Using ARIMA and Factor Analysis
Research article · 4 Apr 2025
Performance, Emission, Vibration Investigation of Waste Chicken Fat Methyl Ester as Fuel and Diethyl Ether as Additive in IC Engine
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Nuclear Energy Science & Power Generation Technology
- SubjectEnergy & Power
- BylineArticles whose byline prints “Mohamad Harastani”
- BylineArticles whose byline prints “Suna Bolat”

