Power distribution and transmission devices can be exposed to voltage transients such as switching and lightning impulse voltages. Usually, impulse voltage withstand tests should be performed in order to reduce the risks of equipment failure. This raises the importance of generating high voltage impulses that make these tests conceivable. For each application, different type of testing waveform is required. These waveforms are defined by specific parameters including the duration, pulse width and raising time among others. Those parameters were partially standardized to organize and regulate different experimental data obtained from various investigations worldwide. In this study, the design aspects of a single-stage standard impulse voltage generator with desired voltage level and output waveform characteristics are detailed. The proposed approach maps the stated literature in [“An Introduction to High Voltage Engineering” by RAY S; “Impulse Testing of a Polluted Insulator with a Dc Bias Voltage” by Shifidi, S K et.al., and so on] into a permissible implementation, in which none of the used components has to be especially built for this purpose. That decreases both the implementation time and cost. Moreover, a verified example on the design of a mobile, low-cost 30 kV standard [1.2/50 μSec] lightning impulse voltage generator is implemented and tested. The validity of the design approach has been conducted both by experiments and simulations with the aid of the Pspice simulation environment in accordance with Kamarudin et.al. This study shows that, the usage of alternating high voltage input (HVAC) with voltage-multipliers that rectify and increase the voltage into a desired level of direct high voltage (HVDC) can be used to trigger a single-stage impulse generator circuit configuration. This approach can be considered as a solution of the accumulated inaccuracies of each stage of multi-stage impulse voltage generators. The overall work results in a mobile, easy to build, low-cost and accurate impulse generator that can eliminate the need of the high cost commercial impulse generator products.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Nuclear Energy Science & Power Generation Technology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Nuclear Energy Science & Power Generation Technology
  • SubjectEnergy & Power
  • BylineArticles whose byline prints “Mohamad Harastani”
  • BylineArticles whose byline prints “Suna Bolat”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels