Scholars Central

Conference abstract

Development of silver nanorods enhanced fluorescence substrate for microarray analysis

Authors: Seok-min Kim

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Metal-enhanced fluorescence is a powerful technology to improve the sensitivity of fluorescence analysis by allowing fluorophores to interact with enhanced electromagnetic fields generated by the localized surface Plasmon resonance (LSPR) effects of metallic nanostructures. To apply metal-enhanced fluorescence technology to disposable DNA or protein microarray analysis, metallic nanostructures need to be fabricated on the full area of a glass slide at low cost. We used a glancing angle deposition (GLAD) process to fabricate Ag nanorods on the whole area of glass slide to serve as an inexpensive and large-area metal-enhanced fluorescence substrate. The GLAD is a physical vapor deposition process in which the substrate is placed at an angle of <15° between the evaporating flux and the substrate surface. When atomic mobility is limited, a self-shadowing effect during deposition results in a highly porous film of isolated nanorods. One can obtain various lengths, densities and shapes of nanorod structures by controlling deposition time, glancing angle and in-plane rotation speed of substrate, respectively. To examine the feasibility of the proposed substrate for the microarray analysis and maximize the signal enhancement, Ag nanorods with different lengths and shape were deposited on glass slides. A 10 nm thick Ni layer and a 40 nm thick Ag layer were sequentially deposited on the glass slide to improve adhesion between the Ag nanorods and the substrate before the GLAD process. To examine the enhancement factor of the GLAD MEF substrates, Streptavidin-conjugated Cy5 was dissolved in buffer solution at 100 ng per ml to 100 μg per ml and spotted onto the substrates. After drying for 24 hours in a refrigerator, the fluorescence signal was measured using a microarray scanner at an excitation wavelength of 635 nm. From the fluorescence measurement experiments, the maximum signal enhancement of ~91x was obtained from the substrate with 750 nm long tilted nanorod structure.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Microbial & Biochemical Technology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Microbial & Biochemical Technology
  • SubjectBiochemistry & Biotechnology
  • BylineArticles whose byline prints “Seok-min Kim”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels