Breast tumor imaging using coded aperture: Monte-Carlo simulation study
King Saud University, Saudi Arabia
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Background: Scintimammography (SM) is a promising functional radionuclide imaging technique that is generally undertaken using high resolution parallel-hole collimators with Gamma Cameras. The main clinical limitation of this technique is inaccuracy in detecting small lesions less than 1 cm diameter. This limitation is due to resolution-efficiency trade-off that is inherent in the use of collimation. As an alternative approach this study proposes using a simple Coded Aperture (CA) mask, instead of a collimator, coupled to a standard clinical gamma camera for breast tumor imaging. This imaging technique successfully predicts the overall form of artefacts arising from the near-field imaging geometries. Aim & Methods: To investigate the applications of CA technique a Monte Carlo Simulation (MCS) is used using MCNPX package. To emulate SM, 3D pseudo-anthropomorphic phantoms have been developed and verified and used along with a realistic model of a clinical gamma camera. This study examines a moderately compressed breast phantom in a cranio-caudalprojection. The performance of such an imaging system is modeled by the MCS method and images are reconstructed by correlation analysis. This imaging system was quantitatively evaluated using variable parameters: The detected photon from tumor, spatial resolution, photon statistics and lesion visibility of the system at several tumor-background activity ratios. The effectiveness and the performance of the CA-SM system was assessed and compared with low energy high resolution parallelhole collimator and ultra-high resolution parallel-hole collimator image formation systems. Results: The predicted background can be used to correct the near-field effect of 3D sources, as might be found in SM using CA. The simulated planar images from these collimator-based image formation systems suggest tumors of 1 cm diameter may be observable with a tumor-background-ratio of 5:1. However, when the tumor diameter is ≤0.8 cm these become less reliable detecting small (less than 1 cm in diameter) lesion unless a tumor-background-ratio of more than 10:1 is used. Conclusion: The results of the simulations demonstrate that with near-field artefacts corrections the CA-SM approach shows good performance in lesion detection for all lesions (located 3 cm deep in a 6 cm thick breast phantom) and for a tumorbackground ratio as low as 3:1. This level of performance is highly competitive, in some cases, superior to conventional collimator based image formation methods.
Subjects
Radiology & ImagingAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Commentary · 2 May 2022
Non Monte Carlo Method for Early Breast Tumor Imaging
Research article · 2018
Investigation of Dosimetric Parameters of HDR Cobalt-60 after-loading Brachytherapy Source using Monte Carlo Fluka Code
Opinion · 1 Dec 2025
Monte Carlo Simulations: Revolutionizing IMRT Dose Calculations
Research article · 30 Sep 2021
Assessment of PET scanner quantitative factors: Analysis and validation of GATE Monte Carlo simulation with experimental study
More from this journal
The newest in Journal of Radiology.
Editorial · 27 Apr 2026
Cardiac Imaging Advancements: Diagnosis, Risk, Treatment
Editorial · 30 Dec 2025
Radiology Safety: Culture, Communication, and Continuous Improvement
Editorial · 30 Dec 2025
Medical Image Quality: Objective, Subjective, and Advanced Assessment
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Radiology
- SubjectRadiology & Imaging
- BylineArticles whose byline prints “Mohammed A Alnafea”
- BylineArticles whose byline prints “A M Alenezi”