Estimate thyroid absorbed dose using I-123 MIBG Imaging
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Purpose: To evaluate use of thyroid blockade prior to AdreView Iobenguane I-123 (GE HealthCare) injection by estimating radiation absorbed dose to patients with I-123 MIBG gamma camera imaging. Methods: A hundred and five patients were administrated with I-123 MIBG, 370 MBq each for adults and adjusted per weight for pediatric patients, through intravenous injection. No thyroid blockade (Potassium Iodide Oral Solution) was used prior to the I-123 injection. Some of the patients had contrast from CT scans before the gamma camera imaging. Whole body planar imaging was performed 24 hours following administration of the radiopharmaceutical. Dual head gamma cameras with LEHR collimators were used to obtain anterior and posterior scans simultaneously. 15% energy window centered at 159 keV was set and scan speed was 9 cm/min. Region of interest (RoI) was defined manually for thyroid and for whole body as well. Geometric mean of the RoI counts from anterior and posterior views was used to calculate absorbed dose. Calibration factor was obtained using total body counts and injected activity. This was done in two ways: using each patient or average of twenty patients. Using the averaged total body counts to generate a single calibration factor would reduce statistical uncertainty. Internal dosimetry software (Olinda/EXM 1.1) was also used to compare the doses. Numbers of disintegrations per unit activity (hr) entered to the Olinda was 17.6 hours based on 25% thyroid uptake. Results: Average effective dose was 49 mrem for whole body and 2.34 mrem for thyroid with the single calibration factor. If individual calibration factors were used, the average effective dose was 207 mrem for whole body and 2.72 for thyroid. The Olinda dosimetry program yielded an effective dose 48 mrem. Conclusions: Gamma camera imaging of I-123 MIBG provided an estimate to thyroid absorbed dose. Accuracy of the dosimetry depends on quantification of the images and calibration factor. The thyroid blockade may not be necessary.
Subjects
Radiology & ImagingAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2015
Experiences from Introducing Standardized High Dose 131I-mIBG Treatment of Children with Refractory Neuroblastoma: Differences in Effective Dose to Patients and Exposure to Caregivers
Research article · 1 Jul 2017
Thyroid shield during brain CT scan: dose reduction and image quality evaluation
Research article · 29 Jul 2020
Estimation the Doses of patients resulting from Diagnostic Cardiac Imaging Modalities
Research article · 2011
Patient Specific 3D Image-Based Radiation Dose Estimates for 90Y Microsphere Hepatic Radioembolization in Metastatic Tumors
More from this journal
The newest in Journal of Radiology.
Editorial · 27 Apr 2026
Cardiac Imaging Advancements: Diagnosis, Risk, Treatment
Editorial · 30 Dec 2025
Radiology Safety: Culture, Communication, and Continuous Improvement
Editorial · 30 Dec 2025
Medical Image Quality: Objective, Subjective, and Advanced Assessment
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Radiology
- SubjectRadiology & Imaging
- BylineArticles whose byline prints “Jianqiao Luo”