Research article · 2011
Conference abstractPublished 13 Sep 2018
Separation selectivity of liquid chromatographic columns. A comparison by nonparametric methods
Hungarian Academy of Sciences, Hungary
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
There are two legitimate aims for column selection: i) to determine similar ones to an existing one, and ii) to find diverse (orthogonal) one(s) for optimal separation. Several different methods have already been elaborated to compare selectivity of chromatographic columns. All comparisons realize empirical approaches and based on measuring retention data of several well-chosen test compounds. Proper multivariate analyses can find similarities and differences in retention behavior of test compounds and stationary phases. As an illustration we adopted Wilson et al.’s data of 67 test compounds and ten highly similar columns (C18-bonded silica stationary phases).1 The inherent characteristic groupings by physical properties were revealed with correct statistical tests and several independent methodologies. Generalized pair correlation method (GPCM)2 and sum of (absolute) ranking differences (SRD)3,4 unambiguously show the same ranking pattern. The clustering by SRD is delivered to the reference. Therefore, all columns have been chosen as gold standard once and only once. (Comparison with One VAriable at a Time.5 All lines of boxes correspond to an SRD ordering always with a different reference column (Figure 1). COVAT heatmaps show destroying the true pattern if the HSM evaluation is used. The ranking (clustering) pattern of chromatographic columns based on retention data (logk values) of 67 compounds, and selectivity parameters of hydrophobic-subtraction model (HSM) provided various column groupings. Loss of information is inevitable if using the HSM data handling. Processing of retention data resulted in patterns that are consistent with differences in the columns’ physicochemical parameters, whereas HSM results are deviating to a higher or lesser degree, depending on the particular chemometric approach. GPCM, SRD and COVAT procedures can be carried out on any data sets partially and on the whole to select the most similar and dissimilar columns, though our calculations were completed to the data set of Wilson et al.1
Subjects
ChemistryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2016
Micellar High Performance Liquid Chromatographic Method for Simultaneous Determination of Clonazepam and Paroxetine HCl in Pharmaceutical Preparations Using Monolithic Column
Research article · 2018
Development of Analytical Method for Separation and Quantification of Cysteine Hydrochloride Monohydrate, Followed by Validation with Total Error Concept by Using Ultra Performance Liquid Chromatography with Pre-Column Derivatization
Research article · 2015
A Validated Chiral Liquid Chromatographic Method for the Enantiomeric Separation of Lacosamide Drug Product and its Dosage Forms
Conference abstract · 16 Jun 2016
Synthesis of composite materials for chromatographic column separations
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- SubjectChemistry
- BylineArticles whose byline prints “Károly Héberger”
