Conference abstract · 20 Apr 2020
Conference abstractPublished 16 Apr 2020
Gas chromatography-mass spectrometry determination of polycyclic aromatic hydrocarbons in water coupled with electroflotation-assisted emulsification liquid–liquid microextraction
N. I. Lobachevsky Nizhny Novgorod State University, Russia
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Polycyclic aromatic hydrocarbons are priority pollutants due to the very high toxicity. Therefore, to determine them, it is necessary to use sensitive methods with preconcentration. In the present study, a novel method named electroflotation-assisted emulsification liquid–liquid microextraction combined with GC-MS analysis has been proposed for the preconcentration and determination of polycyclic aromatic hydrocarbons in water samples. The advantage of electroflotation deemulsification is the ease of changing the gas flow and size of gas micro-bubbles. The formation of gas micro-bubbles occurs on platinum electrodes soldered into a glass concentrator. Hexane, toluene and o-xylene were used as extractants. Application of extract capillary collection have solved the problem of the light extractant sampling. Dispersion of the extractant was performed by ultrasound. The volume of microextracts was 7-10 µl. The recovery of polycyclic aromatic hydrocarbons from water was 62-95%. A DB-5 (5% phenyl + 95% polydimethylsiloxane) fused-silica capillary column (30 m ×0.25 mm i.d. and 0.25-µm film thickness)was applied for separation of the analytes. The limits of detection and quantification of polycyclic aromatic hydrocarbons achieved were at the level of 10-5–10-6 mg/L and highly competitive with the best world results. The methods of accounting or elimination of systematic errors are proposed. Purification of solvents by Rayleigh distillation method allowed to obtain samples with impurity content lower than (1-4)∙ 10-3 mg/L. The expanded uncertainty of determination was calculated. It included precision, uncertainty of standards preparation, calibration, sample introduction, enrichment factor. The relative expanded uncertainty was at the level of 13-30%.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Article · 2020
Gas chromatography-mass spectrometry determination of polycyclic aromatic hydrocarbons in water coupled with electroflotation-assisted emulsification liquidâÂ?Â?liquid microextraction
Research article · 2017
Simultaneous Determination of Polycyclic Aromatic Hydrocarbons, Alkylphenols, Phthalate Esters and Polychlorinated Biphenyls in Environmental Waters Based on Headspace-Solid Phase Microextraction Followed by Gas Chromatography - Tandem Mass Spectrometry
Article · 2017
Simultaneous Determination of Polycyclic Aromatic Hydrocarbons, Alkylphenols, Phthalate Esters and Polychlorinated Biphenyls in Environmental Waters Based on Headspace-Solid Phase Microextraction Followed by Gas ChromatographyÃ?â??Ã? - Tandem Mass Spectrometry
Conference abstract · 2020
Gas chromatography-mass spectrometry determination of polycyclic aromatic hydrocarbons in water coupled with electro flotation-assisted emulsification liquid��?liquid micro extraction
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- SubjectChemistry
- SubjectEnvironmental & Earth Sciences
- BylineArticles whose byline prints “Krylov V. A”
