Research article · 7 Oct 2013
Research articlePublished 19 Nov 2014
Hybrid Iterative Reconstruction Algorithm Improves Image Quality and Helps to Decrease Radiation Dose in 256-Slides Craniocervical CTA
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Purpose: The purpose of this study is to prospectively compare the image quality and radiation dose in two different 256- slice MDCT using Filter Back Projection and iDose4 (Hybrid iterative reconstruction) algorithm craniocervical CT angiography. Materials and methods: Thirty patients were randomly assigned into two groups (Group A and B), each comprising 15 patients. All patients underwent craniocervical CTA examination. Group A (10 men, 5 women; mean age 57.13 ± 11.27; age range 41-73 years) and Group B (9 men, 6 women; mean age 58.80 ± 12.55; age range 41-76 years) received different amount of X-ray tube potential and tube current and underwent on two different version of reconstruction algorithm. Then two blinded radiologist analyzed image quality of craniocervical CTA independently. They performed the subjective image quality and objective image quality assessment. The Effective Radiation Dose (ED) was calculated using CT dose volume Index (CTDIvol.), Dose-Length Product (DLP) and conversion coefficient for chest (conversion factor k=0.014 mSv mGy-1cm-1). We used chi-square test, and Maan-Whitney U test for non-parametric independent t test for subjective evaluation of image quality and to assess inter-observer reproducibility of the image quality by the subjective method between two observers, we used the interclass correlation test. Result: The quantitative image quality of iterative reconstruction algorithm was significant compared to FBP. The mean image noise in group B was 0.51 times lesser than group A (P-value <0.001).The mean image scores in both the groups by radiologist 1 and radiologist 2 was (3.65 ± 0.48 vs. 3.33 ± 0.63 respectively, p=0.002) and (3.73 ± 0.45 vs. 3.40 ± 0.69 respectively, p=0.002). The radiation dose was found to be reduced by 55% in group B compared to group A (P<0.0001) in craniocervical CTA. Conclusion: Hybrid Iterative Reconstruction (HIR) Algorithm significantly improves the image quality in craniocervical CT, as well as helps to lower the radiation dose while maintaining the image quality.
Keywords
Subjects
Radiology & ImagingAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 22 Sep 2016
Pediatric Cardiovascular CT Angiography: Maximizing Image Quality at Low Radiation Dose
Research article · 2 Oct 2012
Radiation dose and image quality evaluation relative to different contrast media using cone-beam CT
Editorial · 5 Oct 2011
Myocardial perfusion imaging: achieving high image quality in half the time or in half the radiation dose
Research article · 2016
Possibilities of Reducing Radiation Dose in Computed Tomography Examinations in Various Age Groups Using an Iterative Model-Based Reconstruction Technique
More from this journal
The newest in Journal of Radiology.
Editorial · 27 Apr 2026
Cardiac Imaging Advancements: Diagnosis, Risk, Treatment
Editorial · 30 Dec 2025
Radiology Safety: Culture, Communication, and Continuous Improvement
Editorial · 30 Dec 2025
Medical Image Quality: Objective, Subjective, and Advanced Assessment
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Radiology
- SubjectRadiology & Imaging
- BylineArticles whose byline prints “Bhoj Raj Sharma”
