Conference abstract · 3 Jul 2013
Conference abstractPublished 27 Apr 2015
Development of a pain detector using microwave radiometry method
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
One of the greatest difficulties in treating patients with pain is the highly subjective nature of pain sensation. The measurement of pain intensity is primarily dependent on the patient?s report, often with little physical evidence to provide objective corroboration. The need is thus clear and urgent for a reliable, non-invasive, non-painful, objective, readily adoptable and coefficient diagnostic platform that provides additional diagnostic information to supplement its current regime with more information to assist doctors in diagnosing these patients. Thus, our idea of developing a pain detector was conceived to take a step further for the detection and diagnosis of chronic and acute pain. Scientific rationale of the idea: Rubrics evaluation of pain states that pain is accompanied by swelling, redness, inflammation, each of which increases with increase in the intensity of pain. Another major point to be noted here is that during pain, due to an injury or any physical damage to the region results in a direct effect on the arteries, causing them to dilate. This increase in diameter of the blood vessels (vasodilation) allows the flow of a larger volume of blood, thereby increasing the localized temperature, relative to the rest of the body. We have used a Microwave radiometer to detect and grade these signals. ?Microwave Radiometer measurements are based on the principle that the intensity of the radiation is directly proportional to temperature in the tissue. It represents a new, non-invasive method that converts electromagnetic radiation from internal tissues at microwave frequencies and provides accurate measurements of the temperature of the patient?s internal organs?. The system of MR possesses an antenna with 2 sensors: a microwave and an infrared. The microwave sensor is 3.9 cm in diameter and detects microwave radiation at 2 to 5 GHz, which corresponds to 7 cm in depth, with accuracy for temperature measurements of 0.20°C. The sensor of MR filters all possible microwaves or radiofrequency waves that may be present in the room vicinity and may cause interference with the sensor. The ?volume under investigation? has a rectangular area of 3 cm in width, 2 cm in length, and 3 to 7 cm in depth depending on the dielectric properties of the underlying tissues, the wavelength, and the water content of the tissue. The second sensor is used for infrared measurements from the skin, for calibrating the microwave sensor readings. The use of microwave sensor will increase the sensitivity of our measurement, and help us grade the intensity of pain as the change in temperature with the intensity is quite small, and requires highly sophisticated measurement devices. We aim to process these signals just like the thermo gram- the regions under pain will be colored significantly different from the rest of the body, which under ideal conditions will maintain uniform body temperature. None the less, the temperature of the body only serves as a baseline or reference point, in order to calibrate our instrument and acclimatize it to the patient. Such a system however, requires expensive materials and methods for fabrication. In an attempt to miniaturize the circuit we will attempt to device a single chip solution in order to achieve optimum integration.
Subjects
Biochemistry & BiotechnologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 3 Dec 2012
An Ultra-Sensitive LC Method for Simultaneous Determination of Rosuvastatin, Alprazolam and Diclofenac Sodium in API, Pharmaceutical Formulations and Human Serum by Programming the Detector
Short communication · Nov 2021
Microwave-Assisted Catalytic Method for a Green Synthesis of Amides Directly from Amines and Carboxylic Acids
Conference abstract · 2018
Effect of microwave pretreatment method on the quality of straw pellets and the agglomeration process
Conference abstract
Selective leaching of molybdenum from spent hydrodesulphurisation catalysts using ultrasound and microwave methods
More from this journal
The newest in Journal of Bioengineering & Biomedical Science.
Article · 29 Dec 2025
Biomaterials For Advanced Implantable Medical Devices
Article · 29 Dec 2025
3D Bioprinting: Personalized Medicine’s Future Frontier
Article · 29 Dec 2025
Microfluidics: Revolutionizing Point-of-Care Diagnostics Speed and Accuracy
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Bioengineering & Biomedical Science
- SubjectBiochemistry & Biotechnology
- BylineArticles whose byline prints “Nanditha Rajamani”
- BylineArticles whose byline prints “Anirudha Rao”
- BylineArticles whose byline prints “Divya Sriram”

