Scholars Central

Conference abstractPublished 10 Aug 2015

Quantification of metformin in human plasma with sold phase extraction using sensitive ultra flow liquid chromatography –tandem mass spectrometric detection

Authors: Raghunadha Reddy Seelama, Nageswara Rao Pillib, Ravindra Reedy Sc, Sai Satyanaraya Reddyc

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

A selective and sensitive method have been developed for quantification of metformin in human plasma by using UFLCâ??MS/MS method. Phenformin was used as an internal standard(IS). The extraction of the metformin from human plasma was performed using solid phase extraction. Inertsil ODS-3 (250x4.6 mm,5μm) reverse phase column was employed for chromatographic separation of metformin and phenformin(IS) for MS/MS detection at 1 ml/min flow using 90:10 (v/v) methanol: 10 mM ammonium acetate. Detection was performed at transitions of m/z 130.000â??71.000 for metformin and m/z 206.100â?? 105.000 for phenformin by positive electro-spray ionization (ESI+) in multiple reaction monitoring (MRM) mode using tandem mass spectrometry. Analysis was carryout within 3.3 min. The calibration curves were linear over a concentration range of 25.0 ng/mL to 3500.0 ng/mL for quantification of Metformin with the correlation coefficients demonstrating good linearity (0.994-0.999). The lower limits of quantification were 25.0 ng/mL for metformin. The developed method was compared in the terms of validation parameters including specificity,linearity, sensitivity, precision, accuracy and stability. The method was shown rugged when new batch was performed with a different column, different analyst and with fresh solutions. No effect was observed in presence of hemolysed or lipemic content in plasma sample and in presence of potentially interfering drugs. Matrix based samples were stable at room temperature for >16 hrs, processed samples were stable at least for >46 hrs and also stable at four freeze-thaw cycles. This validated method was successfully applied for quantification of metformin in human plasma for bioequivalence study.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Pharmaceutical Care & Health Systems.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Pharmaceutical Care & Health Systems
  • SubjectPharmaceutical Sciences
  • BylineArticles whose byline prints “Raghunadha Reddy Seelama”
  • BylineArticles whose byline prints “Nageswara Rao Pillib”
  • BylineArticles whose byline prints “Ravindra Reedy Sc”
  • BylineArticles whose byline prints “Sai Satyanaraya Reddyc”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels