Conference abstract · 22 Aug 2016
Conference abstractPublished 20 Jul 2017
Dynamic wrist imaging using non-gated 4D computed tomographic scanning
Singapore General Hospital, Singapore
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Wrist injuries can lead to static and dynamic instability. Dynamic instability of the wrist often presents with pain but cannot be seen on routine imaging as the instability is only evident during motion. We have previously demonstrated the use of gated 4-dimensional CT (4D CT) to detect and quantify dynamic instability of the wrist. However, the gated CT technique requires wrist motion to be periodic and requires a synchronization signal. The requirement to move in a fixed periodic manner may prove difficult in patients with wrist pain. As such, we developed a truly dynamic CT wrist imaging technique using nongated protocol. Unlike gated CT, non-gated CT imaging does not require periodic and repetitive motion and there is no need for synchronization. To evaluate its efficacy, we scanned five cadaveric wrists during motion. Each cadaveric wrist was mounted on a custom made motion simulator and was scanned while moving in radioulnar deviation at a frequency ranging 10-30 cycles per minute (cpm), through a maximum arc of 30o (10o of radial deviation and 20o ulnar deviation). Data sets were reconstructed at ten different phases of one full motion cycle. We found that we were able to get satisfactory images from the dynamic scan when the motion frequency was less than 15 cpm or at equivalent speed ranging from 9 to 18 mm/s. Motion artifacts were more evident in higher cpm. We have managed to define the boundary motion parameters regard to non-gated 4D CT wrist imaging.
Subjects
Biochemistry & BiotechnologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 10 Sep 2015
Computed Tomographic Scan Findings in Head Injury from a Tertiary Health Facility in South-East Nigeria
Research article · 2012
Computed Tomographic Scanning Measurement of Skull Bone Thickness in Patients with Chronic Tension Type Headache; Case Control Study
Editorial · 2021
Non-Invasive Brain Imaging Technique Chess with Brain-Computer Interface
Research article · 2014
Magnetic resonance imaging-based tennis player wrist joints injury diagnosis
More from this journal
The newest in Journal of Bioprocessing & Biotechniques.
Commentary · 29 Nov 2025
Bioseparation Evolution: Enhanced Efficiency and Selectivity
Commentary · 29 Nov 2025
Advancing Bioprocess Scale-Down: Technologies for Optimization
Brief report · 29 Nov 2025
Bioprocessing Sustainable Packaging Biomaterials: A Review
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Bioprocessing & Biotechniques
- SubjectBiochemistry & Biotechnology
- BylineArticles whose byline prints “Shian-Chao Tay”
- BylineArticles whose byline prints “Ita Suzana Mat Jais”
- BylineArticles whose byline prints “Yoke Rung Wong”