Letter · 18 Jul 2023
Conference abstractPublished 7 Nov 2016
Radiation dose associated with common computed tomography examination
Mansoura University Egypt
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Aim: Aim of this study is to survey computed tomography (CT) radiation dose associated with non-contrast spiral multislice computed tomography exam in our institute. Methods: Survey radiation dose for non-contrast scan of abdomen and pelvis was retrospectively evaluated at Urology Nephrology Center (UNC), Mansoura University using a 64-detector CT scanner. Detailed parameters for 362 consecutive examinations, including the patient weight, height, CTD volume (CTDIvol), scan length, and dose length product (DLP) were recorded from the dose report. Effective dose (E) was estimated for each patient. The differences between E doses were statistically analyzed using SSPS. Results: Patients body mass index (BMI) was 13.4-51.42 (average BMI 29.5 kg/m). Patients dose data (one scan phase for each patient) from dose information: the median value of DLP was 586.45 mGy-cm (83.30 mGy-cm-1179.70 mGy-cm), median value of CTDI was 12.07 (2.20 mGy-23.9 mGy), median value of mAs used was 186.50 (34 mAs-334 mAs). According to international commission of radiological protection (ICRP), effective dose range was (1.1-16.5 mSv) 106 and according to ICRP60, the range was (1.3 to 18.93 mSv). Maiden value of frequent CT examinations for the same patient was 2 (min one scan/year & max 11 scan/year). CT dose variation was highly significant (p value<0.01) depending on high variation on mAs with (r=0.98). CT dose was moderate depending on MBI (r=0.55). Conclusion: There was statistically highly significant variation in effective radiation doses associated with non-contrast CT scan of abdomen and pelvis. The reason for this variation must be avoided.
Subjects
Biochemistry & BiotechnologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 9 Aug 2021
Assessment of Radiation Dose in Computed Tomography Examination of Adult Patient in Abuja and Keffi, Hospitals in Nigerian
Research article · 2019
Evaluation of Radiation Doses in Adult Patients of Routine Computed Tomography Examination in Maiduguri, Borno State, Nigeria
Research article · 2016
Possibilities of Reducing Radiation Dose in Computed Tomography Examinations in Various Age Groups Using an Iterative Model-Based Reconstruction Technique
Conference abstract · 7 Nov 2016
Dosimetric evaluation of a detailed eye model in head computed tomography examinations
More from this journal
The newest in Journal of Bioengineering & Biomedical Science.
Article · 29 Dec 2025
Biomaterials For Advanced Implantable Medical Devices
Article · 29 Dec 2025
3D Bioprinting: Personalized Medicine’s Future Frontier
Article · 29 Dec 2025
Microfluidics: Revolutionizing Point-of-Care Diagnostics Speed and Accuracy
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Bioengineering & Biomedical Science
- SubjectBiochemistry & Biotechnology
- BylineArticles whose byline prints “Ayman Mokhtar”
- BylineArticles whose byline prints “Maysa Abd El-Hamid”
- BylineArticles whose byline prints “Huda Refaie”
- BylineArticles whose byline prints “Tarek El-Diasty”
- BylineArticles whose byline prints “Sabry El Mogy”

