Article · 29 Jul 2025
Conference abstractPublished 10 Sep 2018
Dynamic guided surgery with Navident
Marigold Dental and Orthodontic Clinic, UAE
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Dynamic Guided Surgery is a surgical technique applied to implant placement in dentistry. It is a natural evolution of static guided surgery, where a stereo-lithographic template is used to guide implant placement. In fact, it shares with static guided prosthetic driven surgery approach, but it stands apart as such it does not need the use of any surgical guide. Navident 2.0, the newer version has streamlined the workflow reducing to three the former four stage workflow. Dynamic guided surgery is enabled thanks to Claro Navâ??s patent, a Canadian company, branded as Micron Tracker. This patent takes advantage of the stereoscopy principle that was well known starting from last century. Human beings have a 3D vision because have two eyes. They empower an angular view along with a linear one. On the same fashion, two cameras, independently from each other as our eyes, capture 3D patientâ??s anatomy and match it on 3D CBCT dicom files. In this way, clinicians can navigate through images and not through templates. Dynamic guided surgery workflow unfolds in either four or three distinctive steps: First, Workflow (1): A radiologic stent manufacturing, called Navistent, (2) CBCT patient scanning, while wearing a Navistent, (3) Case planning using Navident software and (4) dynamic implant placement. Second, Workflow (1) Standard CBCT either only two cotton rolls separating the arches, (2) Case planning using Navident software, (3) Trace and Place: tracing the surface of minimum 3 teeth (max 6) and then dynamic implant placement. Dynamic guided surgery depending on the type of workflow in use, it sees either for the four step workflow, the use of a Jaw Tag and a Drill Tag that get read by the two stereoscopic cameras. The first refers to patient anatomy, the second to contrangle or straight hand piece position in the space. For the three-step workflow the use of a Head tracker/Jaw tracker and the Drill tag.
Subjects
SurgeryAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Opinion · 28 Feb 2025
Advancements in image-guided surgery and transplant case studies: Implications for modern surgical practice
Editorial · 31 Jan 2025
A study on the efficacy of tumor-specific targeting agents in guiding resection during robotic-assisted gastrointestinal cancer surgeries.
Editorial · 31 Jan 2025
Application of MRI-Guided Surgery in Planning and Executing Precision Breast Cancer Resections
Editorial · 30 Jan 2025
Restoring Mobility: A Comprehensive Guide to Joint Replacement Surgery
More from this journal
The newest in Journal of Surgery.
Brief report · 1 Dec 2025
Innovations in Sutures for Abdominal Wall Repair
Brief report · 1 Dec 2025
Surgical Checklists: Improving Safety and Efficiency
Commentary · 1 Dec 2025
Thermal Injury In Vascular Surgery: Minimizing Risks
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Surgery
- SubjectSurgery
- BylineArticles whose byline prints “Shaikh Anwar Hussain”

