Scholars Central

Research articlePublished 2015

Spatio-Temporal Electrode Mapping and Local Interleaved Stimulation Method (STEMLIS) for Artificial Sight Systems

Authors: Mustafa Ozden, Irfan Karagoz

Journal of Bioengineering & Biomedical Science

Volume 5 · Issue 3 · Pages 1–12

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Image processing algorithms play a key role in the development of visual prosthesis systems. In this study, a new electrode stimulation method for retinal implant systems, “Spatio-Temporal Electrode Mapping and Local Interleaved Stimulation (STEMLIS),” is proposed. In this method, the most meaningful spikes that preserve the spatial discrimination in a temporal frame are selected as stimulation data, and phase shifts are applied to all sub electrode groups to minimize undesired electrode interactions. By using this method, both spatial and temporal resolution of stimulation data can be enhanced, since spatio-temporal mapping is used while selecting the stimulation data from a large number of spike data for stimulation of the low-numbered electrode matrix placed on retina surface. The phase delays between the neighboring electrodes are used to introduce interleaved pulses, which minimize the electrical interactions. To evaluate the contribution of the STEMLIS method to perceived image quality, computer based quantitative simulation studies and visual evaluation tests with normal seeing people were performed. For quantitative evaluation, the outputs for the classical method and the STEMLIS method were compared based on the mean squared error (MSE), the histogram similarity ratio (HSR), and edge discrimination parameters. In visual tests, performance of the method was evaluated in terms of contrast discrimination, pattern recognition, text reading and object counting tasks. The subjects reached higher test scores with proposed method and better scores obtained in quantitative comparison. It is concluded that spatio-temporal enhancement of stimulation data can help to improve perceived image quality on visual prostheses.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Bioengineering & Biomedical Science.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Bioengineering & Biomedical Science
  • SubjectBiochemistry & Biotechnology
  • BylineArticles whose byline prints “Mustafa Ozden”
  • BylineArticles whose byline prints “Irfan Karagoz”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels