Conference abstract · 12 Mar 2018
Research articlePublished 2012
Measuring Blood Pressure in the Office: The Argument for Wider Clinical Use of Automated Devices
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Objective: Accurate measurement of blood pressure (BP) remains a fundamental step in diagnosing and managing hypertension. The aim of this study is to evaluate the accuracy of office BP measurement using an automated office blood pressure (AOBP) device (BpTRU®) performed in a 5-minute cycle. Participants and methods: 117 consecutive patients (mean age 55 ± 17 years, 60% women) referred for management of hypertension over a nine-month period are included in this study. BP readings with the BpTRU® device (BP recorded five times in five minutes), mean awake ambulatory blood pressure (ABP), and routine BP readings taken in the patient’s primary care physician (PCP) office were compared. Results: Average of 5 BP readings for mean blood pressure using the AOBP device was similar to the mean awake ABP (systolic BP 133 ± 4 mmHg vs.135 ± 3 mmHg; (p = 0.2) and diastolic BP 80 ± 2 mmHg vs. 79 ± 2 mmHg; (p = 0.7)). Both systolic AOBP and awake ABP values were significantly lower than the systolic BP recorded in PCP office (144 ± 5 mmHg) (p < 0.001). The coefficient of correlation between the systolic/diastolic AOBP and the average of awake ABP (r = 0.70/0.72) was highly significant (p < 0.001). With the AOBP device, the first systolic reading was significantly higher than the average of the 2nd to 6th systolic readings (141 ± 2 mmHg vs. 133 ± 4 mmHg, p < 0.001). Conclusion: BP measurement performed with the AOBP device in a 5-minute cycle more accurately measures BP in a physician office setting when compared to single BP measurement. Relying on the1st BP measurement or a single reading may lead to over estimation of BP.
Subjects
Nephrology & UrologyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Short communication · 31 Mar 2021
Dr Allen′s device for kidney care by dissolving renal calculi naturally prevents people with kidney stone disease from the development of secondary high blood pressure or diabetes
Short communication · 2021
Dr Allenâ?²s device for kidney care by dissolving renal calculi naturally prevents people with kidney stone disease from the development of secondary high blood pressure or diabetes
Conference abstract · 12 Mar 2018
Dr Allen's device for kidney care by dissolving renal calculi naturally prevents people with kidney stone disease from the development of secondary high blood pressure or diabetes
Research article · 17 Sep 2020
24 Hours ambulatory blood Pressure (Abpm) monitoring characteristics and correlation with hemodilysis blood pressures measures
More from this journal
The newest in Journal of Nephrology & Therapeutics.
Research article · 15 Apr 2026
Anemia Management in Hemodialysis Patients in a Low-resource Setting: Blood Transfusion and Unmet Blood Needs in Burkina Faso
Brief report · 30 Mar 2026
Renal Fibrosis: Targeting Pathways For New Therapies
Brief report · 30 Mar 2026
SGLT2 Inhibitors: A New Era for Diabetic Kidney Disease
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Nephrology & Therapeutics
- SubjectNephrology & Urology
- BylineArticles whose byline prints “Thomas G”
- BylineArticles whose byline prints “Doleh T”
- BylineArticles whose byline prints “Rafey MA”
- BylineArticles whose byline prints “Gebreselassie S”
- BylineArticles whose byline prints “Butler R”
- BylineArticles whose byline prints “Emmanuel L Bravo”

