Research article · 2017
Conference abstractPublished 3 Sep 2018
Evolutionary DVH-evaluation for beam orientations in intensity-modulated radiation
Taibah University, Saudi Arabia
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The problem of beam orientations in intensity-modulated radiation therapy (IMRT) is an important, but large-scale NP-hard optimization problem. A considerable part of this difficulty is due to the essential prerequisite of defining, appropriately, counter-intuitive criteria for a mathematical plan evaluation that coincides with the clinical judgment of the considered plan. Moreover, the quality of beam directions depends heavily on its corresponding beam intensity profiles. Usually a stochastic selector is utilized for optimizing beam orientations, and an inverse treatment planning algorithm is employed to optimize beam intensity profiles for every selection of beam orientations. Thus, intensity profiles are calculated many thousands of times, each time for a different selection of beam directions, resulting in excessive time complexity. Therefore selecting an appropriate set of beam directions in IMRT is still a time-consuming manual trial-and-error search procedure that depends on intuition and empirical knowledge. To overcome these difficulties, this work utilizes the concept of dose volume histogram (DVH), which is one of the main recognized quantitative measurement tools used for plan judgment, to present a DVH evaluation scheme that parallelizes plan evaluation with clinical plan judgment. The DVH evaluation scheme is then combined with an evolutionary algorithm manufactured particularly to solve the problem of beam orientation in IMRT. The results of applying the presented methods to real clinical cases demonstrated that while the evolutionary algorithm converges to appropriate solutions in practical clinical time slot, significant improvement were reported in all clinical cases in comparison to the standard equally spaced beam plans, even when sometimes using a fewer number of beams. A fewer number of beams is always desirable without compromising the quality of the treatment plan. This results in a shorter treatment delivery time which reduces potential errors in terms of patient movements and decreases discomfort, as well as the risk of reoccurring cancers in the future.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Mini review · 27 Feb 2021
Intensity-Modulated Radiation Therapy: A Review
Conference abstract · 3 Sep 2018
Effect of fluence smoothing on the quality of intensity-modulated radiation treatments
Conference abstract · 24 Aug 2015
Comparison of simultaneous integrated boost intensity-modulated radiation therapy and conventional accelerated hyper-fractionated radiotherapy for limited disease small-cell lung cancer
Conference abstract · 24 Aug 2015
Comparison of simultaneous integrated boost intensity-modulated radiation therapy and conventional accelerated hyper-fractionated radiotherapy for limited disease small-cell lung cancer
More from this journal
The newest in Journal of Molecular Imaging & Dynamics.
Conference abstract · 26 Oct 2021
X-ray confirmation of nasogastric tube placement: documentation in patient notes
Conference abstract · 26 Oct 2021
The Hacked Unconscious Mind-The Root Cause of Cancer
Conference abstract · 26 Oct 2021
THE AGONY OF A CANCER PATIENT IN AFRICA, AND NIGERIA IN PARTICULAR
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Molecular Imaging & Dynamics
- SubjectGenetics & Molecular Biology
- SubjectRadiology & Imaging
- BylineArticles whose byline prints “Ahmad-Saher Azizi-Sultan”