Sterilization Validation of Gas Plasma Exposure Based on ISO Documents (Mainly ISO TC 198 And 194 Documents)
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
There are so many ISO documents to understand and utilize for validation studies and routine control. A biological indicator (BI) is essential for conducting sterilization validation and routine control. ISO 11138-1 and ISO 14161 are the major documents to follow for BI manufacturers and BI users, respectively. In ISO 11138-1, BI manufacturers must utilize a BI with 106 CFU/carrier as an initial population for validation studies. For routine control, it is approved to use an initial BI population of 105 CFU/carrier according to ISO 11138-1. In ISO 14161 BI users need not imitate BI manufacturers and less than 106 CFU/carrier BI is approved for use in validation studies and routine control. According to ISO 14161 for BI users, the initial population must be identical for validation studies and routine control. For the BI user, there are four types of procedures for sterilization validation and routine control. These are the half-cycle, over-kill, combined BI/bioburden and the absolute bioburden methods. A BI with An initial population of 106 CFU/ carrier must be used for validation studies by BI manufacturers according to ISO 11138-1, but BI users can elect to use a commercially available BI with more than 103 CFU/carrier as the BI for validation studies and routine control as described in ISO 14161. The approved SAL was defined to be 10-6 and this is unchanged for both BI users and BI manufacturers. Therefore, from the initial population of 106 CFU (colony forming unit)/carrier to a SAL of 10-6, the survivor curve must be straight and tailing is not allowed as described below (ISO 11138-1). The BI used for gas plasma sterilization, spores of Geobacillus stearothermophilus ATCC 7953, has characteristics that do not result in a tailing phenomenon. A linear survival curve is obtained from an initial population of 106 CFU/carrier to a SAL 10-6 for all sterilization procedures tested, demonstrating that inactivation kinetics are first order and allowing calculation of the D (decimal reduction) value from the dose or time to decrease 1 log. Chemical indicators (CI) are not approved for use in validation studies; only the use of BI is approved. CIs are only approved for use as a supporting method during routine control according to ISO 11140-1 and 14161. Only a BI is approved for both validation studies and routine control according to ISO 14161.
Subjects
Pharmaceutical SciencesAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2014
Role of Metastable and Spore Hydration to Sterilize Spores by Nitrogen Gas Plasma Exposure and DPA Analysis by HPLC and UV
Editorial · 2015
Considering an Important Point When Handling Gas Plasma Sterilization
Editorial · 2015
The Gas Plasma Sterilization
Review article · 2015
Simultaneous Achievement of Sterility Assurance Level (SAL) of 10-6 and Material and Functional Compatibility in Gas Plasma Sterilization Running Title: Simultaneous SAL and Compatibility
More from this journal
The newest in Pharmaceutical Regulatory Affairs: Open Access.
Article · 13 Feb 2026
Regulatory Scenario of Pharmaceuticals during COVID-19 Pandemic in India
Article · 11 Feb 2026
EU GMP Annex 1 of 2022: A View in Depth
Article · 11 Feb 2026
Standard Formats Used in Drug Regulatory Submissions and Software Used
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalPharmaceutical Regulatory Affairs: Open Access
- SubjectPharmaceutical Sciences
- BylineArticles whose byline prints “Hideharu Shintani”