Optical communication technology is the only way to achieve larger transmission capacity with longer transmission distance. To accommodate the increasing demand of data transfer and high-speed optical telecommunication, networks with terabit transmission capabilities without the optical to electronic conversion is demonstrated by combining optical time division multiplexing (OTDM) and wavelength division multiplexing (WDM). Mach-Zehnder Interferometer (MZI) is widely used in the WDM. It contains two input signal ports and two output signal ports associated with electrode that can change the refractive index of one of its arm. Due to the application of the voltage, the electric field generates around the particular arms of the MZI. Hence, due to variation in the electric field, the phase difference arises. The phase difference introduced in the signal is responsible for the phenomena whether the signal will exist in the same waveguide or will shift on the other waveguide. The switching between the ports of MZI can be achieved by an electro-optic effect within such type of structure. Using this concept, a device is constructed to calculate the 1?s Complement Bit pattern. Various optical switches and signal router can be designed keeping in mind the utility of MZI.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 2018
Generation of Arbitrary Waveform Based on Optical Frequency Comb Using a Dual Parallel Mach-Zehnder Modulator and an Optical Filter
Conference abstract · 2018
Optical frequency comb generation utilizing Mach-Zehnder modulator and multi-laser sources
Conference abstract · 6 Jan 2016
The Mach Zehnder Interferometer biosensor for single nucleotide DNA testing with two missmatches bases in the BRCA-1 gene
Review article · 31 Dec 2014
Mach-Zelder Interferometer Switching Applications using photonic Integrated Circuits for Optical routing (A review)
More from this journal
The newest in Biosensors & Bioelectronics.
Article · 29 Dec 2025
Advancing biosensing for microbial monitoring
Brief report · 29 Dec 2025
Advancing Biosensors for Personalized Health Monitoring
Brief report · 29 Dec 2025
Hybrid Biosensors: Enhanced Detection for Health
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalBiosensors & Bioelectronics
- BylineArticles whose byline prints “Santosh Kumar”
- BylineArticles whose byline prints “S K Raghuwanshi”
- BylineArticles whose byline prints “Ajay Kumar”