Conference abstract · 27 Jul 2015
Conference abstractPublished 17 Jun 2013
Wireless surface electrical stimulation with knee joint angle measurement system using gyroscope and flex bend sensors
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The purpose of this study is to develop a wireless FES rehabilitation system to assist effective improvement of the lower limbs especially for Spinal Cord Injury (SCI) patients such as paraplegia. In this report, a prototype system combined with knee joint angle measurement using wireless surface electrical stimulator and the wireless MEMS vibratory gyroscope and flex bend sensors was developed and evaluated. Zigbee wireless modules were used for communication between controller and stimulator units in order to reduce wiring complexity and reduce movement limitation. In Body Sensor Network (BSN) field for medical purpose, body join tangle measurement system is quite important and useful for continuous monitoring in rehabilitation activities especially for Spinal Cord Injury (SCI) patients. Body join tangle measurement system is sensory type system that provides information about angle movement of body joint. It is usually used at knee and arm joint to monitor the movement while patients do some exercises. This is very important and helpful to the therapists and physicians in order to see the effectiveness of rehabilitations training. For knee angle movement evaluation, lower limb joint angles and segment angles were estimated by the Kalman filter from the data measured with wireless MEMS vibratory gyroscope and flex bend sensors. Electrical stimulation was applied to the common peroneal nerve or the tibialis anterior muscle by detecting stimulus timing automatically from the data of wireless sensor attached on the back of knee which known as popliteal fossa and shank of the paraplegic side. The developed system was performed well in monitoring the effectiveness of rehabilitations training and the measured data of the gyroscope and flex bend sensors showed the characteristics and difference of paralyzed side with and without electrical stimulation using the segment angles and joint angles.
Subjects
Energy & PowerOrthopaedicsAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Perspective · 28 Feb 2023
Electrical Systems Real-Time Control and Monitoring with Wireless Sensor Networks
Conference abstract · 11 Sep 2017
The effect of Progressive Resistance Exercises (PRE) with knee flex device made by researcher to increase muscular power and ROM after knee arthroplasty operation
Research article · 2020
A microfluidic-based sensor with a built-in probe for conformal mechanical measurements of different anatomical sites at the exterior surface of human Pectus Carinatum (PC) costal cartilage
Research article · 2020
A microfluidic-based sensor with a built-in probe for conformal mechanical measurements of different anatomical sites at the exterior surface of human Pectus Carinatum (PC) costal cartilage
More from this journal
The newest in Biosensors & Bioelectronics.
Article · 29 Dec 2025
Advancing biosensing for microbial monitoring
Brief report · 29 Dec 2025
Advancing Biosensors for Personalized Health Monitoring
Brief report · 29 Dec 2025
Hybrid Biosensors: Enhanced Detection for Health
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalBiosensors & Bioelectronics
- SubjectEnergy & Power
- SubjectOrthopaedics
- BylineArticles whose byline prints “Babul Salam K. K. Ibrahim”
- BylineArticles whose byline prints “Aizan Masdar”
- BylineArticles whose byline prints “M. Mahadi Abdul Jamil”
- BylineArticles whose byline prints “Dirman Hanafi”

