Article · 29 Dec 2025
Conference abstractPublished 14 May 2012
Interdigitated microelectrode-based impedance sensors for E-coli detection
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Diseases caused by Escherichia coli (E-coli) have been a serious threat to public health and food safety for decades and remain one of the major concerns of our society. The urinary tract is the most common site of E-coli infection, and more than 90% of all uncomplicated urinary tract infections (UTI) are caused by E-coli infection. Diagnosing UTI usually relies on conventional detection methods (bacteria culture) which are time consuming and labor-intensive. Although more rapid detection methods are available, such as dip-stick method for E-coli detection, they provide insufficient sensitivity. In this study, rapid detection of E-coli in urine is carried out by impedance measurement using gold interdigitated microelectrodes (IDME) with enhanced sensitivity. Our interdigitated microelectrode sensor is designed with gold surface area of about 0.4 mm2, since lower detection limits can be achieved by this small electrode area. The stability of the sensors under AC electric field is characterized by measuring capacitance in air and by measuring impedance in phosphate buffer solution (PBS). The capacitance of the sensors measured in air at 100 mV is 2.8 pF with 8 % coefficient of variation, and also the capacitance remains same in the frequency range of 500 Hz to 1 MHz. As electrode features become smaller, the sensitivity of the system is enhanced because the impedance changes are increased. Using this approach, low concentration detection would be possible. The aim of this study was focused on wide range detection from low to high concentration in urine and to optimize the lower detection limit of E-coli in urine suspension. This impedance detection technique with gold interdigitated microelectrode shows promising potential for application in UTI diagnosis. This technique can also be applied for the detection of E-coli in contaminated food and water samples.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Biosensors & Bioelectronics.
Brief report · 29 Dec 2025
Advancing Biosensors for Personalized Health Monitoring
Brief report · 29 Dec 2025
Hybrid Biosensors: Enhanced Detection for Health
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalBiosensors & Bioelectronics
- BylineArticles whose byline prints “C.J. Chen”
- BylineArticles whose byline prints “J.Z. Tsai”
- BylineArticles whose byline prints “S. Kalpana”
- BylineArticles whose byline prints “J.T. Liu”

