Scholars Central

Research articlePublished 2011

Tomographic Normal Values for Corneal Elevation and Pachymetry in a Hyperopic Population

Authors: Joan T. Kim, Michael Cortese, Michael W. Belin, Renato Ambrosio Jr, Stephen S. Khachikian

Journal of Clinical and Experimental Ophthalmology

Volume 2 · Issue 2 · Pages 1–4

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Purpose: To establish a normative data base with respect to corneal pachymetry and elevation tomography appropriate for refractive surgery screening of hyperopic individuals. Methods: 100 eyes of 51 consecutive hyperopic patients were examined with the Oculus Pentacam HR to determine corneal pachymetry and anterior and posterior elevation values at the apex and thinnest point. All patients were otherwise screened as normal and all principal meridians were hyperopic. Results were compared to a previously studied data base of myopic individuals from the same practice. Results: The average corneal thickness at the apex and thinnest point was not significantly different between the hyperopic and myopic groups (P>0.05 at both locations). The mean anterior elevation at the apex was0.4 ± 1.9 µm in the hyperopic group vs. 1.6 ± 1.3 µm in the myopic group (P<0.001). The mean anterior elevation at the thinnest point was-0.1 ± 2.2 µm in the hyperopic group vs. 1.7 ± 2.0 µm in the myopic group (P<0.001). The mean posterior elevation at the apex was5.7 ± 3.6 µm in the hyperopic group vs. 0.8 ± 3.0 µm in the myopic group (P<0.001). The mean posterior elevation at the thinnest point was10.6 ± 5.7 µm for the hyperopic group vs. 3.6 ± 4.1 µm for the myopic group (P<0.001). When adjusted for age, the posterior elevation changes remained statistically significant. Conclusions: Hyperopic individuals exhibited greater variation in posterior tomographic elevation values than a comparable myopic group. Currently used data bases need to be adjusted for screening hyperopic individuals to reduce the number of false positives associated with using a myopic biased data set.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Journal of Clinical and Experimental Ophthalmology.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalJournal of Clinical and Experimental Ophthalmology
  • SubjectOphthalmology & Optometry
  • BylineArticles whose byline prints “Joan T. Kim”
  • BylineArticles whose byline prints “Michael Cortese”
  • BylineArticles whose byline prints “Michael W. Belin”
  • BylineArticles whose byline prints “Renato Ambrosio Jr”
  • BylineArticles whose byline prints “Stephen S. Khachikian”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels