Article · 17 Feb 2026
Research articlePublished 2018
UV Detection on Artificial Uric Acid Using UV-Vis Spectrometer
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
The aim of this research work is to measure the concentration and absorption cross-section of artificial uric acid in the Ultraviolet (UV) region using UV-Vis spectrometer. The uric acid sample comes in powder form which has to be dissolved with distilled water to convert it into liquid form. Therefore, it can be placed in the cuvette for the analysis purposes. This research study was proposed to make a comparison with the previous research studies that uric acid was normally extracted from human serum as a real sample. This research study was carried out using an artificial sample of uric acid with the suspended or grits of uric acid which were not totally dissolved. These grits might be artificially assumed as crystallites which is common with Gout disease. Based on the medical perspective, crystallites normally inhibit the human joints which may cause intense pain to the human bones or tissues. In the experiment, the distilled water was used a background or reference spectrum which can be stored and automatically deducted using the Spectra suite software application. Thus, Spectra suite only measures the pure concentration and UV absorption wavelength of the uric acid through the use of the spectrometer. The absorbance data was extracted and substituted into Beer’s Lambert Law formula to calculate the value of absorption cross-section. The result shows that the value of UV absorption wavelength and absorption cross-section is really close as reported in the previous research studies. It proves that even the artificial sample of uric acid with the grits still can give a very close result. The UV absorption of uric acid was obtained at 293.99 nm by four different concentrations. The response time was successfully done in 3 seconds. The resulting curves have noise signals which can be analyzed and reduced using an averaging method to make the curve look sharper and lack of noise.
Subjects
Physics & AstronomyAsk about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
More from this journal
The newest in Journal of Lasers, Optics & Photonics.
Brief report · 29 Nov 2025
Lasers Revolutionize Medicine: Diagnostics, Surgery, Therapy
Opinion · 29 Nov 2025
Silicon Photonics: Advancing Scalable, Cost-effective Optical Networks
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Lasers, Optics & Photonics
- SubjectPhysics & Astronomy
- BylineArticles whose byline prints “Norazmi N”
- BylineArticles whose byline prints “Abdul Rasat ZR”
- BylineArticles whose byline prints “Mohamad M”
- BylineArticles whose byline prints “Manap H”