Research article · 4 Nov 2016
Research articlePublished 2015
Tremor Assessment - On Disability Scale and Functional Performance Test
Abstract
Select any words in the title or abstract, or press this and choose a sentence.
Tremor is the most common movement disorder. The objective of the current study was to find correlation between disability due to tremor (daily living score) with the functional performance tests like nine-hole peg and box and block. A total of 100 subjects with tremor, categorized in seven diagnostic groups fulfilling the respective diagnostic criteria studied. Clinical assessment using activities of daily living scales (ADL-T24) and tremor severity score done on each patient. The nine-hole peg score (in seconds) and box and block score (number of blocks in 60 seconds) calculated in each. We found that tremor severity was proportionate to ADL-T24 score and had a positive correlation with the disease duration. Overall, there was a moderate positive correlation between ADL-T24 score and 9-HPT score (R2=0.52) whereas a strong negative correlation between ADL-T24 and BBT score (R2=-0.66). An inverse pattern was observed between 9-HPT score and BBT score with a moderate negative correlation (R2=-0.58). It was concluded that the functional performance tests correlate well with the daily living scores. Thus the tremor severity can be quantified on time based measures and are useful for tremor assessment.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Research article · 24 Apr 2015
Performance assessment of molecular and microscopy tests for detection of trypanosoma species in glossina fuscipes fuscipes (diptera: glossinidae) midguts in Kajo-Keji county, South Sudan.
Research article · 2012
ECOG or Karnofsky Performance Status to Assess Functionality in Glioblastoma Patients Among Different Observers
Research article · 2019
Precision Performance of the Chengdu Seamaty SMT-100, Point of Care Test (POCT) Device for General Chemistry and Liver Function Panels – A Manufacturer and Customer Laboratory Experience
Article · 2019
Precision Performance of the Chengdu Seamaty SMT-100, Point of Care Test (POCT) Device for General Chemistry and Liver Function Panels Ã?¢Ã?â?¬Ã?â?? A Manufacturer and Customer Laboratory Experience
More from this journal
The newest in Journal of Molecular Biomarkers & Diagnosis.
Brief report · 29 Dec 2025
Biomarker Discovery To Clinical Translation: A Holistic Approach
Commentary · 29 Dec 2025
Molecular Diagnostics: Revolutionizing Precision Healthcare
Commentary · 29 Dec 2025
Genomic Biomarkers Revolutionizing Disease Diagnosis and Medicine
Conferences in this field
Upcoming conferences in this field.
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalJournal of Molecular Biomarkers & Diagnosis
- SubjectGenetics & Molecular Biology
- SubjectPathology & Lab Medicine
- BylineArticles whose byline prints “Man Mohan Mehndiratta”
- BylineArticles whose byline prints “Munish Kumar”
- BylineArticles whose byline prints “Sanjay Pandey”

