Scholars Central

Research articlePublished 2019

A Novel Three Dimensional Conformal Radiation Therapy Technique to Decrease the Mean Parotid Gland Dose in Whole Brain Radiation Therapy

Authors: Lara Hilal, Hana Mekdash, Paul Ramia, Mustafa Jammal, Dima Mahmoud, Bilal Shahine, Toufic Eid, Wassim Jalbout, Helena Abdul Khalek, Fady Geara, Youssef H. Zeidan, Bassem Youssef

Nuclear Medicine & Radiation Therapy

Volume 10 · Issue 2 · Pages 1–3

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

Purpose: Whole brain radiation therapy remains standard for patients with multiple brain metastases not amenable to stereotactic irradiation. Incidental irradiation of the parotid glands can result in xerostomia. A novel technique (NT) using 3D conformal radiotherapy was used to decrease the radiation dose to the parotid glands and hence the risk of xerostomia. Methods: CT simulations of 20 de-identified patients were randomly selected. For each patient, 3 different WBRT plans were generated. The first using the standard opposed laterals fields with the inferior border at C2, the second with the inferior border at C1 and the third using a NT. In the NT, we placed the isocenter 0.5-1 cm superior to the contoured parotid glands. Superior to the isocenter, two lateral fields were designed similar to the standard opposed laterals. Inferior to the isocenter, 2 oblique fields were used, conformal to the contoured brain, with a 1 cm collimation to the edge of the MLC. Prescription dose was 30 Gy in 10 fractions for all plans. Brain coverage and the means of the right, left and bilateral parotids were compared in each of the plans. Results: In all three techniques of WBRT, brain coverage was adequate with 95% of the dose covering more than 95% of the brain volume. The average of the mean right parotid dose using C2, C1, and the NT were 17.7 Gy ± 4.4, 12.3 Gy ± 3.3, and 5.6 Gy ± 2.1. The average of the mean left parotid dose using C2, C1, and the NT were 18.3 Gy ± 4.2, 13.0 Gy ± 3.1, and 6.2 Gy ± 1.5. The average of the mean bilateral parotids dose using C2, C1, and the NT were 18.0 Gy ±4.0, 12.6 Gy ±2.8, and 5.8 Gy ±1.8. Conclusion: Our simple new 3DCRT technique for WBRT significantly reduces mean parotid gland dose compared to the standard techniques.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

Similar by topic

More from this journal

The newest in Nuclear Medicine & Radiation Therapy.

All its articles

Conferences in this field

Upcoming conferences in this field.

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalNuclear Medicine & Radiation Therapy
  • SubjectRadiology & Imaging
  • SubjectEnergy & Power
  • BylineArticles whose byline prints “Lara Hilal”
  • BylineArticles whose byline prints “Hana Mekdash”
  • BylineArticles whose byline prints “Paul Ramia”
  • BylineArticles whose byline prints “Mustafa Jammal”
  • BylineArticles whose byline prints “Dima Mahmoud”
  • BylineArticles whose byline prints “Bilal Shahine”
  • BylineArticles whose byline prints “Toufic Eid”
  • BylineArticles whose byline prints “Wassim Jalbout”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels