Abstract
Select any words in the title or abstract, or press this and choose a sentence.
This work presents a parametric electrical modelling of the electrical response of human forearm tissues through a simulation of Multi-frequency Electrical Bioimpedance analysis (MF-EBIA). The objective is to estimate an electrical equivalent representation for tissue response in terms of resistance and capacitance values for three tissue layers in the forearm – the fat, muscle and artery, using parametric fitting analysis. Following up from a simulation study of the human forearm model using Ansys® High Frequency Structure Simulator (HFSS), this work assumes an electrical model of the human forearm section for every tissue and calculates the electrical parameters. The tissue model was considered to be isotropic with regards to the dielectric properties and the consideration of blood flow was realised by taking three instances of radial artery diameter. The proposed model was validated by using the obtained values of model components to reproduce the overall response. The obtained values of resistance and capacitance for every tissue domain provide an insight into their significant contribution to the overall electrical response, which can be important while analysing their individual electrical behaviour and also helpful in various pre-experimental studies related to dielectric characterization of living tissues.
Ask about this article
Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.
Similar by topic
Conference abstract · 7 Nov 2016
Parametric electrical modelling of human forearm simulation response using multi-frequency electrical bioimpedance
Research article · 2016
Chronic Neck Pain Assessment using Multi-Frequency Bioimpedance
Research article · 2018
Frequency Analysis and Simulation of a Good Ground System to Protect Medical Electric Equipment Installed In Ilam Hospital
Research article · 2013
Robust Modeling of Human Thermal Response to Hand and Forearm cooling for Improved Performance and Energy Efficiency
More from this journal
The newest in Biosensors & Bioelectronics.
Article · 29 Dec 2025
Advancing biosensing for microbial monitoring
Brief report · 29 Dec 2025
Advancing Biosensors for Personalized Health Monitoring
Brief report · 29 Dec 2025
Hybrid Biosensors: Enhanced Detection for Health
Follow
New articles from what you follow go into your email digest, once you agree to alert emails.
- JournalBiosensors & Bioelectronics
- SubjectEnergy & Power
- SubjectMathematics & Statistics
- BylineArticles whose byline prints “An”
- BylineArticles whose byline prints “Lowe A”
- BylineArticles whose byline prints “Al-Jumaily AM”