Scholars Central

Research articlePublished 7 Feb 2017

Cdse/Zns Capped Thiolate for Application in Glucose Sensing

Authors: Samsulida Abd. Rahman, Nurhayati Ariffin, Nor Azah Yusof, Jaafar Abdullah, Zuhana Ahmad Zubir, Nik Mohd Azmi Nik Abd Aziz

Industrial Biotechnology Research Centre (IBRC), SIRIM Berhad, Section 2, Shah Alam, Selangor, Malaysia; Advanced Materials and Nanotechnology Laboratory, Institute of Advanced Technology, Universiti Putra Malaysia, UPM Serdang, Selangor, Malaysia; Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, UPM, Serdang, Selangor, Malaysia; Advance Material Research Centre (AMREC), SIRIM Berhad, Lot 34, Kulim Hi-Tech Park, Kulim, Kedah Darul Aman, Malaysia

Biosensors Journal

Volume 6 · Issue 1 · Pages 1–5

Ask about this article

Abstract

Select any words in the title or abstract, or press this and choose a sentence.

A semiconducting water soluble core-shell quantum dot (QD) capped with thiolated ligand is used in this study for application in glucose sensing. These QDs were prepared in house based on hot injection technique. The ZnS shell at the outer surface of CdSe core QDs is made via specific process namely, SILAR (successive ionic layer adsorption and reaction). The distribution, morphology and optical characteristics of prepared core shell QDs have been assessed by transmission electron microscopy (TEM) and spectrofluorescence, respectively. The results show that the mean particle size of prepared QDs is in the range of 10-12 nm and the optimum emission condition was displayed at 620nm. The prepared CdSe/ZnS core shell QDs were modified by utilizing six organic ligands L-cysteine, L-histidine, thio-glycolic acid (TGA), mercapto-propionic acid (MPA), mercapto-succinic acid (MSA) and mercapto-undecanoic acid (MUA) at room temperature through a ligand-exchange procedure. This ligand exchange process was chosen in order to produce a very dense water solubilizing agent the QDs surrounding surface. The result shows that CdSe/ZnS capped with thioglycolic acid (CdSe/ZnS-TGA) exhibit the strongest fluorescence emission; therefore it was used in advanced sensing application for the detection of glucose. The highly active CdSe/ZnS-TGA was then interacted with Glucose Oxidase enzyme (GOx) and horseradish peroxidase enzyme (HRP). In this study, determination of glucose level is depending on the QDs fluorescence intensity quenching effect, which is correlated to reaction of the conjugated enzyme-QDs. In the presence of 0.1 mM glucose, fluorescence intensity of the bioconjugate QDs was quenched about 12, 000 a.u. This bioconjugated GOX/HRP/QDs-capped TGA was further analyzed with known concentrations of glucose. Quenched fluorescence intensity was proportionate with glucose concentration. The resultant GOX/HRP/QDs-capped TGA system can be a suitable platform for glucose determination in real samples.

Ask about this article

Answers come only from this article's title, abstract and keywords, each sentence pointing to where it comes from. Your question is sent to OpenAI to write the answer. Scholars Central does not store it.

Try:

More from this journal

The newest in Biosensors Journal.

All its articles

Follow

New articles from what you follow go into your email digest, once you agree to alert emails.

  • JournalBiosensors Journal
  • SubjectEnvironmental & Earth Sciences
  • SubjectNanotechnology
  • SubjectPhysics & Astronomy
  • BylineArticles whose byline prints “Samsulida Abd. Rahman”
  • BylineArticles whose byline prints “Nurhayati Ariffin”
  • BylineArticles whose byline prints “Nor Azah Yusof”
  • BylineArticles whose byline prints “Jaafar Abdullah”
  • BylineArticles whose byline prints “Zuhana Ahmad Zubir”
  • BylineArticles whose byline prints “Nik Mohd Azmi Nik Abd Aziz”

For authors and organisers

Publish, present and keep up with your field

Find the right journal for your paper and submit your manuscript.

Photo: Pexels